An outbreak of new coronavirus SARS-CoV-2 was occurred in Wuhan, China and rapidly spread to other cities and nations. The standard diagnostic approach that widely adopted in the clinic is nucleic acid detection by real-time RT-PCR. However, the false-negative rate of the technique is unneglectable and serological methods are urgently warranted. Here, we presented the colloidal gold-based immunochromatographic (ICG) strip targeting viral IgM or IgG antibody and compared it with real-time RT-PCR. The sensitivity of ICG assay with IgM and IgG combinatorial detection in nucleic acid confirmed cases were 11.1%, 92.9% and 96.8% at the early stage (1-7 days after onset), intermediate stage (8-14 days after onset), and late stage (more than 15 days), respectively. The ICG detection capacity in nucleic acid-negative suspected cases was 43.6%. In addition, the concordance of whole blood samples and plasma showed Cohen's kappa value of 0.93, which represented the almost perfect agreement between two types of samples. In conclusion, serological ICG strip assay in detecting SARS-CoV-2 infection is both sensitive and consistent, which is considered as an excellent supplementary approach in clinical application.
Background SARS-CoV-2 has caused millions of deaths, and, since Aug 11, 2020, 20 intramuscular COVID-19 vaccines have been approved for use. We aimed to evaluate the safety and immunogenicity of an aerosolised adenovirus type-5 vector-based COVID-19 vaccine (Ad5-nCoV) in adults without COVID-19 from China. Method This was a randomised, single-centre, open-label, phase 1 trial done in Zhongnan Hospital (Wuhan, China), to evaluate the safety and immunogenicity of the Ad5-nCoV vaccine by aerosol inhalation in adults (≥18 years) seronegative for SARS-CoV-2. Breastfeeding or pregnant women and people with major chronic illnesses or history of allergies were excluded. Participants were enrolled and randomly assigned (1:1:1:1:1) into five groups to be vaccinated via intramuscular injection, aerosol inhalation, or both. Randomisation was stratified by sex and age (18–55 years or ≥56 years) using computer-generated randomisation sequences (block sizes of five). Only laboratory staff were masked to group assignment. The participants in the two aerosol groups received an initial high dose (2 × 10 10 viral particles; HDmu group) or low dose (1 × 10 10 viral particles; LDmu group) of Ad5-nCoV vaccine on day 0, followed by a booster on day 28. The mixed vaccination group received an initial intramuscular (5 × 10 10 viral particles) vaccine on day 0, followed by an aerosolised booster (2 × 10 10 viral particles) vaccine on day 28 (MIX group). The intramuscular groups received one dose (5 × 10 10 viral particles; 1Dim group) or two doses (10 × 10 10 viral particles; 2Dim group) of Ad5-nCoV on day 0. The primary safety outcome was adverse events 7 days after each vaccination, and the primary immunogenicity outcome was anti-SARS-CoV-2 spike receptor IgG antibody and SARS-CoV-2 neutralising antibody geometric mean titres at day 28 after last vaccination. This trial is registered with ClinicalTrials.gov, number NCT04552366. Findings Between Sept 28, 2020, and Sept 30, 2020, 230 individuals were screened for inclusion, of whom 130 (56%) participants were enrolled into the trial and randomly assigned into one of the five groups (26 participants per group). Within 7 days after vaccination, adverse events occurred in 18 (69%) in the HDmu group, 19 (73%) in the LDmu group, 19 (73%) in the MIX group, 19 (73%) in the 1Dim group, and 15 (58%) in the 2Dim group. The most common adverse events reported 7 days after the first or booster vaccine were fever (62 [48%] of 130 participants), fatigue (40 [31%] participants), and headache (46 [35%] participants). More adverse events were reported in participants who received intramuscular vaccination, including participants in the MIX group (49 [63%] of 78 participants), than those who received aerosol vaccine (13 [25%] of 52 participants) after the first vaccine va...
An outbreak of new coronavirus SARS-CoV-2 was occurred in Wuhan, China and rapidly spread to other cities and nations. The standard diagnostic approach that widely adopted in the clinic is nuclear acid detection by real-time RT-PCR. However, the false-negative rate of the technique is unneglectable and serological methods are urgently warranted. Here, we presented the colloidal gold-based immunochromatographic (ICG) strip targeting viral IgM or IgG antibody and compared it with real-time RT-PCR. The sensitivity of ICG assay with IgM and IgG combinatorial detection in nuclear acid confirmed cases were 11.1%, 92.9% and 96.8% at the early stage (1-7 days after onset), intermediate stage (8-14 days after onset), and late-stage (more than 15 days), respectively. The ICG detection capacity in nuclear acid-negative suspected cases was 43.6%. In addition, the consistencies of whole blood samples with plasma were 100% and 97.1% in IgM and IgG strips, respectively. In conclusion, serological ICG strip assay in detecting SARS-CoV-2 infection is both sensitive and consistent, which is considered as an excellent supplementary approach in clinical application.
To date, the pathogenesis of severe acute respiratory syndrome (SARS) in humans is still not well understood. SARS coronavirus (SARS-CoV)-specific CTL responses, in particular their magnitude and duration of postinfection immunity, have not been extensively studied. In this study, we found that heat-inactivated SARS-CoV elicited recall CTL responses to newly identified spike protein-derived epitopes (SSp-1, S978, and S1202) in peripheral blood of all HLA-A*0201+ recovered SARS patients over 1 year postinfection. Intriguingly, heat-inactivated SARS-CoV elicited recall-like CTL responses to SSp-1 but not to S978, S1202, or dominant epitopes from several other human viruses in 5 of 36 (13.8%) HLA-A*0201+ healthy donors without any contact history with SARS-CoV. SSp-1-specific CTLs expanded from memory T cells of both recovered SARS patients, and the five exceptional healthy donors shared a differentiated effector CTL phenotype, CD45RA+CCR7−CD62L−, and expressed CCR5 and CD44. However, compared with the high avidity of SSp-1-specific CTLs derived from memory T cells of recovered SARS patients, SSp-1-specific CTLs from the five exceptional healthy donors were of low avidity, as determined by their rapid tetramer dissociation kinetics and reduced cytotoxic reactivity, IFN-γ secretion, and intracellular production of IFN-γ, TNF-α, perforin, and granzyme A. These results indicate that SARS-CoV infection induces strong and long-lasting CTL-mediated immunity in surviving SARS patients, and that cross-reactive memory T cells to SARS-CoV may exist in the T cell repertoire of a small subset of healthy individuals and can be reactivated by SARS-CoV infection.
We study the technique to adjust the performance of a piezoelectric bimorph vibrating in the flexural mode through axial preloads, which is useful for a power harvester to effectively scavenge energy from ambient mechanical vibrations/noise with varying-frequency spectra. The external circuit connected to the bimorph is simplified as an impedance in the analysis. Analytical solutions are derived. The analyses show that resonance happens when the natural frequency of the bimorph is adjusted adjacent to the external driving frequency by preloading, and the output power density can be raised many more times in that case. The mechanism for an axial preload to improve the bimorph performance at varying-frequency vibrations is examined in detail.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.