In this work, we successfully demonstrate a fast method to determine the fish freshness by using a sensing system containing an ultrasensitive amine gas sensor to detect the volatile amine gas from the raw fish meat. When traditional titration method takes 4 h and complicated steps to test the total volatile basic nitrogen (TVB-N) as a worldwide standard for fish freshness, our sensor takes 1 min to deliver an electrical sensing response that is highly correlated with the TVB-N value. When detecting a fresh fish with a TVB-N as 18 mg/100 g, the sensor delivers an effective ammonia concentration as 100 ppb. For TVB-N as 28-35 mg/100 g, a well-accepted freshness limit, the effective ammonia concentration is as 200-300 ppb. The ppb-regime sensitivity of the sensor and the humidity control in the sensing system are the keys to realizing fast and accurate detection. It is expected that the results in this report enable the development of on-site freshness detection and real-time monitoring in a fish factory.
In this work, a TFB (poly[(9,9-dioctylfluorenyl-2,7-diyl)-co-(4,4'-(N-(4-s-butylphenyl)diphenylamine)]) sensor with a cylindrical nanopore structure exhibits a high sensitivity to ammonia in ppb-regime. The lifetime and sensitivity of the TFB sensor were studied and compared to those of P3HT (poly(3-hexylthiophene)), NPB (N,N'-di(1-naphthyl)-N,N'-diphenyl-(1,1'-biphenyl)-4,4'-diamine), and TAPC (4,4'-cyclohexylidenebis[N,N-bis(4-methylphenyl) benzenamine]) sensors with the same cylindrical nanopore structures. The TFB sensor outstands the others in sensitivity and lifetime and it shows a sensing response (current variation ratio) of 13% to 100 ppb ammonia after 64 days of storage in air. A repeated sensing periods testing and a long-term measurement have also been demonstrated for the test of robustness. The performance of the TFB sensor is stable in both tests, which reveals that the TFB sensor can be utilized in our targeting clinical trials. In the last part of this work, we study the change of ammonia concentration in the breath of hemodialysis (HD) patients before and after dialysis. An obvious drop of breath ammonia concentration can be observed after dialysis. The reduction of breath ammonia is also correlated with the reduction of blood urea nitrogen (BUN). A correlation coefficient of 0.82 is achieved. The result implies that TFB sensor may be used as a real-time and low cost breath ammonia sensor for the daily tracking of hemodialysis patients.
We report the construction of a polymer space-charge-limited transistor (SCLT), a solid-state version of vacuum tube triode. The SCLT achieves a high on/off ratio of 3×105 at a low operation voltage of 1.5 V by using high quality insulators both above and below the grid base electrode. Applying a greater bias to the base increases the barrier potential, and turns off the channel current, without introducing a large parasitic leakage current. Simulation result verifies the influence of base bias on channel potential distribution. The output current density is 1.7 mA/cm2 with current gain greater than 1000.
Point-of-care (POC) application for monitoring of breath ammonia (BA) in hemodialysis patients have emerged as a promising non-invasive health monitoring approach. In this context, many organic gas sensors have been reported for BA detection. However, one of the major challenges for its integration with portable POC application is to achieve long lifetime and high operational current at low voltage. Herein, we propose a double active layer (DL) strategy that exploits an ultra-thin layer of Poly(3hexylthiophene-2,5-diyl) (P3HT) to serve as a work function buffer, combined with an acceptor-donor polymer Poly [[4,8-as a new sensing material. We show that the DL sensor exhibits a sustainable enhanced operational current of microampere level and a stable sensing response even with the presence of P3HT layer. This effect is carefully examined with different aspect, including vertical composition profile of DL configuration, lifetime testing on different sensing layer, morphological analysis, and the versatility of the DL strategy. Finally, we utilize the CT/P3HT-DL sensor to conduct a long-term tracing of BA concentration in two hemodialysis (HD) patients before and after HD, and correlate it with the blood urea nitrogen (BUN) levels. A good correlation coefficient of 0.96 is achieved. The result demonstrates the potential of this DL strategy to be used to integrate organic sensor in POC devices.
External quantum efficiency versus charge carriers mobility in polythiophene/methanofullerene based planar photodetectorsThe direct influence of the vertical carrier mobility on the frequency response of bilayered organic photodiodes ͑PDs͒ is investigated for the first time. With fullerene as the acceptor material, changing vertical hole mobility from 2.3ϫ 10 −5 to 2.8ϫ 10 −4 cm 2 / V s increases PD bandwidth from 10 to 80 MHz under a 4 V operation. The influence of deposition rate on vertical hole mobility of pentacene film is also discussed. Our results facilitate the application of bilayered organic PDs on the detection of very-high-frequency optical signals.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.