Because of the narrow interradicular spaces and varying oral anatomies of individual patients, there is a very high risk of root proximity during the mini implants inserting. The authors hypothesized that normal occlusal loading and implant loading affected the stability of miniscrew implants placed in proximity or contact with the adjacent root. The authors implemented finite element analysis (FEA) to examine the effectiveness of root proximity and root contact. Stress distribution in the bone was assessed at different degrees of root proximity by generating 4 finite element models: the implant touches the root surface, the implant was embedded in the periodontal membrane, the implant touches the periodontal surface, and the implant touches nothing. Finite element analysis was then carried out with simulations of 2 loading conditions for each model: condition A, involving only tooth loading and condition B, involving both tooth and implant loading. Under loading condition A, the maximum stress on the bone for the implant touching the root was the distinctly higher than that for the other models. For loading condition B, peak stress areas for the implant touching the root were the area around the neck of the mini implant and the point of the mini implant touches the root. The results of this study suggest that normal occlusal loading and implant loading contribute to the instability of the mini implant when the mini implant touches the root.
To investigate the cause of mandibular implant loss, we evaluated the stress distribution in the bone under bite force when the miniimplant was near the root using three-dimensional finite element analysis. Our analysis involved four finite element models with different distances between the implant and adjacent tooth root and three loading conditions. With loading of the tooth only or both the tooth and implant, the peak stress within the bone around the implant neck, displacement, and stress surrounding the bone near the root increased as the distance between the implant and root decreased. However, with separate loading of the implant, the stress did not correlate with the distance between the implant and root. Application of bite force increases stress within bones surrounding mini-implants near the roots of adjacent teeth and may threaten implant stability, but simple orthodontic loading has little effect on the stress distribution at the mini-implant-bone interface.
This study aims to elucidate the biomechanical effects of combined loading of maxillary anterior and posterior implants using the sliding method on en-masse retraction of the anterior teeth and to quantify the loading ratio (LR) of anterior and posterior implants to achieve controlled retraction of the maxillary anterior teeth. A three-dimensional finite element model of the maxilla-upper dentition appliance was constructed. Implants were placed on the distal (A) and mesial (B) sides of the lateral incisors as well as on the mesial (C) side of the first molar and different amounts of force were loaded between the implants using 2- or 5-mm traction hooks. The labiolingual movement of the anterior teeth was recorded and the relationship between the LR of the implants and the movement of the central incisors was evaluated. With 2-mm traction hooks, the central incisors exhibited a translation tendency during retraction at lower A/C and B/C LR and labial or lingual crown inclination at higher values. With 5-mm traction hooks, the central incisors, lateral incisors, and canine teeth exhibited a labial crown inclination. The results of this study suggest that 2-mm traction hooks can cause labial crown inclination, translation tendency during retraction, or lingual crown inclination of the central incisors due to alterations in the LR of the anterior and posterior implants. The central incisors only exhibited labial crown inclination during combined loading of the anterior and posterior implants when 5-mm traction hooks were used.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.