High serum ferritin level was associated with a high risk of glaucoma in men, but not in women. Because serum ferritin is related to oxidative stress and inflammation, it might play a role in glaucoma development.
The objective of this study was to evaluate postoperative clinical outcomes of photorefractive keratectomy (PRK) using different ablation frequencies. In this prospective, contralateral eye study, 56 eyes of 28 patients with myopia or myopic astigmatism were included. PRK was performed using the MEL90 excimer laser system (Carl Zeiss Meditec, Germany). One eye of each patient was treated with a repetition rate of 250 Hz, while the other one was treated with a repetition rate of 500 Hz. The treatment pattern in the 250 Hz and 500 Hz group only differed in terms of ablation frequency; there was no difference in laser pulse energy, spot size or ablation profile. Postoperative follow-ups were at 3 and 7 days and 1, 3 and 6 months. The following parameters were assessed: Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), higher-order aberrations (HOAs), corneal re-epithelisation time and corneal haze. Ablation depth was proportional to laser pulse counts at both frequencies. At 6 months, 100.0% of the eyes in the 250 Hz group and 96.4% in the 500 Hz group had a UDVA of 0.00 logMAR or better; 100% of the eyes in both groups were within ± 1.00D of the attempted correction. All eyes had a postoperative CDVA of 0.00 logMAR or better. There was no difference between the groups in postoperative HOAs, corneal re-epithelisation time or corneal haze. Photorefractive keratectomy with a repetition rate of 250 Hz and 500 Hz showed comparable efficacy, safety and predictability in the correction of myopia. There were no significant complications due to the high repetition rate, such as postsurgical corneal haze.
The Korean Intermittent Exotropia Multicenter Study (KIEMS) was a retrospective, cross-sectional and multicenter study for the investigation of intermittent exotropia involved 65 strabismus specialists from 53 institutions in Korea. Purpose of this study was to present ophthalmologic findings of intermittent exotropia from the KIEMS. Consecutive patients with intermittent exotropia of ≥ 8 prism diopters (PD) at distance or near fixation were included. Best-corrected visual acuity, cycloplegic refraction data, angles of deviation at several cardinal positions, ocular dominance, fusion control, oblique muscle function, and binocular sensory outcomes were collected. A total of 5385 participants (2793 females; age 8.2 years) were included. Non-dominant eye was more myopic than the dominant eye (− 0.60 vs. − 0.47 diopters, P < 0.001). Mean exodeviation angles were 23.5 PD at distance and 25.0 PD at near fixation. Basic type (86.2%) was the most, followed by convergence insufficiency (9.4%) and divergence excess (4.4%) types. Alternating ocular dominance and good fusion control were more common at near than at distance fixation. Good stereopsis at 40 cm was observed in 49.3% in Titmus stereo test (≤ 60 arcsec) and in 71.0% in Randot stereo test (≤ 63 arcsec). Intermittent exotropia was mostly diagnosed in childhood and patients with the condition showed relatively good binocular functions. This study may provide objective findings of intermittent exotropia in a most reliable way, given that the study included a large study population and investigated comprehensive ophthalmology examinations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.