The hermeticity and diffusion behavior of “epi-seal” encapsulation [R. N. Candler et al., J. Microelectromech. Syst. 15, 1446 (2006); B. Kim et al., Proceedings of the ASME 2007 InterPACK Conference (InterPACK’07), 33234 (2007)], an epitaxially deposited polysilicon film encapsulation for microelectromechanical systems (MEMSs), were investigated. MEMS resonators with pressure sensitive quality factor were fabricated inside episeal cavities. By measuring the quality factor and inferring cavity pressure, leakage through the encapsulation was studied as a continuation of previous hermeticity investigations [B. Kim et al., Proceedings of the 2004 ASME International Mechanical Engineering Congress and Exposition, IMECE, pp. 413–416 (2004)]. During long-term monitoring performed at 100 °C in a normal atmosphere, the encapsulated cavity pressure increased at a rate of 5–10 mTorr/yr, whereas no measurable pressure change could be detected in our previous room temperature measurement performed with identically designed and encapsulated resonators. To identify the cause of this pressure increase, the diffusive gas species and diffusion pathways in the epi-seal encapsulation were investigated experimentally. Various gas species in the atmosphere were tested in a 400 °C accelerated environment. These tests identified hydrogen and helium as highly diffusive gas species and showed argon and nitrogen to be much less diffusive under these conditions. Also, a series of devices with modifications of encapsulation geometry was tested in a hydrogen environment at 400 °C. Silicon dioxide, used for sacrificial and passivation layers, was identified as the primary diffusion pathway through the epi-seal encapsulation. These experimental results and diffusion pathway models were compared with the diffusion activation energy of various gas species in semiconductor materials, enabling design and process optimization for improved hermeticity of wafer-scale thin-film encapsulation for MEMS devices.
The frequency stability of single-crystal silicon microelectromechanical systems resonators encapsulated with epitaxial polysilicon (epi-seal) is investigated. As silicon resonators have significant temperature dependence, the inherent frequency stability of the resonators is masked by temperatureinduced noise. Using two resonators side-by-side and assuming identical temperatures and fluctuations, temperature effects are eliminated, resulting in the two resonators tracking each other within ±10 ppb, or 3 × 10 −4°C , over a month. Power and thermal cycling the resonators produced no observable effects on the resonant frequency. This result indicates that silicon resonators make excellent on-chip thermometers, or high stability timing references if temperature is compensated well.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.