The objective of this paper is to present a new type of volumetric CT which uses the cone-beam technique instead of traditional fan-beam technique. The machine is dedicated to the dento-maxillo-facial imaging, particularly for planning in the field of implantology. The main characteristics of the unit are presented with reference to the technical parameters as well as the software performance. Images obtained are reported as various 2D sections of a volume reconstruction. Also, measurements of the geometric accuracy and the radiation dose absorbed by the patient are obtained using specific phantoms. Absorbed dose is compared with that given off by spiral CT. Geometric accuracy, evaluated with reference to various reconstruction modalities and different spatial orientations, is 0.8-1% for width measurements and 2.2% for height measurements. Radiation dose absorbed during the scan shows different profiles in central and peripheral axes. As regards the maximum value of the central profile, dose from the new unit is approximately one sixth that of traditional spiral CT. The new system appears to be very promising in dentomaxillo-facial imaging and, due to the good ratio between performance and low cost, together with low radiation dose, very interesting in view of large-scale use of the CT technique in such diagnostic applications.
The associations between abdominal visceral fat and the plasma hemostatic system were examined in 38-year-old healthy men (n=52) with a wide range of fatness and fat distribution. Plasma hemostatic factors and metabolic parameters, including glucose tolerance, were measured, and body fatness and adipose tissue distribution were assessed by using computed tomography. The men with more visceral fat (ie, higher than the median value [n=26]) had a less favorable metabolic profile than the men with less visceral fat (n=26). They also had significantly (P<.05) higher plasma fibrinogen, factor VIII clotting activity, tissue-type plasminogen activator antigen, and plasminogen activator inhibitor-1 (PAI-1) activity (19.2+/-2.4 versus 8.5+/-1.6 AU/mL, P<.001) and lower basal tissue-type plasminogen activator activity. After adjustment for plasma insulin, the men with larger abdominal visceral fat area still had significantly higher plasma PAI-1 activity, but no difference was found in any of the other hemostatic factors. In multiple linear regression analysis, abdominal visceral fat area was a positive predictor of plasma PAI-1 activity, but it failed to show any significant association with other hemostatic factors after controlling for plasma insulin. These results suggest the presence of relationships between abdominal visceral fat and several plasma hemostatic factors that are largely mediated by concomitant alterations in plasma insulin concentration. In addition, our results suggest that abdominal accumulation of visceral fat is an independent predictor of plasma PAI-1 activity.
As patients with previous history of pancreatitis were excluded from the study, CT findings allowed correct characterization of only 60% of cystic pancreatic masses. Among the remaining 40%, 15-20% of the wrong diagnoses could not be corrected by means of CT, given the patterns shown by the tumors. In 20-25% of the cases, a nonspecific diagnosis of cystic mass was made.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.