A number of orthoses have been designed to restore stance and walking in paraplegic subjects. Among them, the reciprocating gait orthosis (RGO) appears to be one which is most widely adopted. The great energetic cost of orthotically aided walking is the main factor limiting the walking capability of paraplegic subjects. The purpose of the present research was to give a complete biomechanical evaluation of RGO locomotion in order to provide data that can be used for further improvements of the orthosis. From the whole body kinematics the mechanical work done to move the orthosis was estimated; by measuring the actual metabolic cost of RGO locomotion the efficiency was evaluated as the ratio between mechanical work and energy expenditure. It is found that RGO locomotion is a very demanding task in terms both of energy expenditure and of the mechanical work required. Furthermore, it is evident that the major determinant of this poor efficiency of RGO locomotion is the enormous amount of work required to move the orthosis which, in turn, reflects its poor mechanical characteristics. To accomplish the demand of real mobility, devices for transferring work from the upper to the lower portion of the body must be substantially improved. This technical aspect must be parelleled by suitable training programmes especially designed to improve the aerobic power of paraplegic subjects and their body composition (ie less fat and more muscle).
SummaryThe aim of this work was to provide well defined criteria for ramp construction for wheel chair dependent individuals (WDl). Force capability was measured in a large sample (140) of WDI, who presented different levels of motor impairment. Levels of impairment were established on the basis of the answers given in a questionnaire regarding the degree of self sufficiency at home as well as outside the home and active participation in sports events. Taking into account those WDI who exhibited at least a minimal level of self sufficiency, the following prescriptions are indicated. For a 1 metre ramp length, allow able maximal incline 15%; up to 3 metre ramp length, maximal incline 10%. The relia bility of such prescriptions was confirmed by having a test ramp traversed by 43 WDI.These values are suggested as confidence limits when faced with public building accom modations. Special prescriptions could be adopted for selected populations of WDI.
No abstract
A reciprocating gait orthosis (ROO) is, among others, the most widely adopted device to restore the standing and walking capability of paraplegic patients. The aim of the present s�udy was the evaluation of the energy demand (V02), and cardiopulmonary load (HR and VE) imposed on the subject by different working tasks while sitting in a wheelchair or standing using a ROO. In addition, a comparison with the performance of normal subjects was also attempted. The ROO use allowed a dramatic improvement of patients mobility and reach space in the workplace. A further advantage provided by the use of the ROO was represented by the increased mobility of the subjects with respect to the wheelchair confined situation. The energy demand and the cardiorespiratory load imposed on the subjects by the use of the ROO were not different from those observed both in the same subjects sitting in a wheelchair and in the controls. The energy demand slightly exceeded the values typical of light work and was, thus, compatible with the normal duration of a working day. On the other hand, the cardiac load corresponded to that typical of moderate activity, thus limiting the duration of the working task to 5-8 h. Based on the ergometry test, all of the working activities considered can be classified as aerobic activities, energy demand being under the ventilatory threshold.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.