This prospective study evaluated the hypothesis that emergence agitation after electroconvulsive therapy (ECT) could be caused by lactate-induced panic secondary to insufficient neuromuscular blockade. Plasma lactate levels were measured before and after 245 consecutive ECT sessions in 37 patients monitored for evidence of post-ECT agitation. ECT was administered using a brief-pulse, rectangular, constant-current device through bilaterally placed electrodes under general anesthesia and neuromuscular blockade. Agitation was observed in 7% of all ECT sessions. No significant difference could be found in pre-ECT lactate levels. However, mean post-ECT lactate levels in agitated sessions were significantly greater than those in nonagitated sessions (4.77 versus 2.54 mmol/l, p < 0.05). An increase (+27%) in the pre-ECT succinylcholine dose for those patients who previously had repeated post-ECT agitation resulted in cessation of post-ECT agitation and return of the formerly high post-ECT lactate levels to normal (1.61 versus 2.07 mmol/l). Although the number of patients who had post-ECT agitation was small, the data support the hypothesis that post-ECT agitation might be a manifestation of lactate-induced panic.
Fluvoxamine is an antidepressant drug introduced into the clinic in 1986. It acts by selectively inhibiting neuronal serotonin recapture. It can be quantified by several meth ods, including high performance liquid chromatography. The HPLC method used so far needs special equipment and has poor sensitivity. The technique is difficult and time consuming. An easier, quicker and more sensitive HPLC assay for the routine determination of fluvoxamine in human plasma has therefore been developed. After alkalinisation and direct extraction by a mixture of n-hexane-isoamylic alcohol 985: 15 (v/v) of plasma samples, the organic phases were further extracted by HCl 0.1 N. Thirty μL of the final extract (with loxapine as internal standard) were injected directly into a C-8 column with a mobile phase consisting of 370 mL acetonitrile, 0.4 mL diethylamine, 630 mL of distilled water, 25 mL pic B5. UV detection at 254 nm was used. The whole process was completed in 40 min. The detec tion limit was 10 ng mL-1. No interference was found either with several benzodiazepines or with antidepres sant drugs commonly associated during treatments.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.