After irradiation with 7 and 9 MeV protons, activation-induced effects were encountered in measurements of current-voltage ͑IV͒ and capacitance-voltage ͑CV͒ characteristics for Czochralski and float-zone grown silicon particle detectors prepared on printed circuit boards with copper electrodes. With the present detector construction, the 30 Si͑p , n͒ 30 P and 63 Cu͑p , n͒ 63 Zn reactions induce dominant interference in such measurements. The daughter nuclides are positron emitters with half-lives of 2.5 and 38.5 min, respectively, and the slowing down of the emitted positrons generates a significantly large concentration of electron-hole pairs in the detector volume increasing the leakage current level and decreasing the breakdown voltage. The observed time-dependent characteristics were verified by modeling the activation of the detector structure and the resulting leakage current. As a result, the electrical measurements cannot be performed immediately after irradiation due to silicon activation, and, generally, materials becoming easily activated should be avoided in the detector concept.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.