Purpose: This study aimed to examine the reliability of trunk extensor strength assessment with a functional electromechanical dynamometer (FEMD). Methods: Thirty-one men performed strength assessment at different velocities (V) (V1 = 0.15 m·s−1, V2 = 0.30 m·s−1, V3 = 0.45 m·s−1) and range of movement (R) (R1 = 25% cm; R2 = 50% cm), and isometric contraction at 90º. Reliability was obtained through the intraclass correlation coefficient (ICC), typical error (TE), and coefficient of variation (CV). Results: The absolute reliability provided stable repeatability of the average eccentric strength in the V1R1 condition (CV = 9.52%) and the maximum eccentric strength in V1R1 (CV = 9.63%) and V2R2 (CV = 9.66%). The relative reliability of the trunk extensor’s average strength was good (ICC = 0.77–0.83) for concentric and good (ICC = 0.78–0.85) and moderate (ICC = 0.67–0.74) for eccentric contraction. Also, good (ICC = 0.77–0.81) and moderate (ICC = 0.55–0.74) reliability of the maximum strength were obtained for concentric and eccentric contraction. The most reliable manifestation to evaluate the concentric (CV = 11.33%) and eccentric (CV = 9.52%) strength was the average strength in the V1R1 condition and the maximum strength (CV = 10.29%) to isometric assessment. The average concentric strength in the V2R2 condition (r = 0.69) and the maximum eccentric strength in the V1R1 condition (r = 0.65) were the best related to the maximum isometric strength. Conclusions: FEMD is a highly reliable device to evaluate trunk extensors strength.
Background: The purpose of this systematic review was to: (I) determine the quality of evidence from studies assessing trunk isokinetic strength in subjects with acute low back pain (ALBP) compared to healthy subjects and (II) establish reference values of isokinetic trunk strength in subjects with ALBP. Methodology: Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) statements were followed using keywords associated with trunk, strength and low back pain. Four databases were used: PubMed, Web of Science, Scopus and SPORTDiscus. Methodological quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS). Results: A total of 1604 articles were retrieved, four included in this review. All were evaluated as high risk of bias (Rob). Due to the high Rob and the diversity of protocols, instruments and variables used, it was not possible to determine reference values for subjects with ALBP, we can only establish a range of flexion peak torque (PT) between 175.1 and 89.7 Nm at 60°/s and between 185 and 81.5 Nm at 120°/s, and for extension PT between 240.0 and 91.5 Nm at 60°/s and between 217.5 and 69.2 Nm at 120°/s in subjects with ALBP. Conclusions: Due to the low quality of the evidence and the diversity of protocols used when measuring trunk isokinetic strength, it is necessary to carry out new high-quality research to establish reference values of trunk strength in subjects with ALBP.
The purpose of this study was to investigate the acute effect of pre-activation with Variable Intra-Repetition Resistance and isometry on the overhead throwing velocity in handball players. Fourteen female handball players took part in the study (age: 21.2 ± 2.7 years, experience: 10.9 ± 3.5 years). For Post-Activation Potentiation, two pre-activation methods were used: (I) Variable Intra-Repetition Resistance: 1 x 5 maximum repetitions at an initial velocity of 0.6 m·s-1 and a final velocity of 0.9 m·s-1; (II) Isometry: 1 x 5 s of maximum voluntary isometric contraction. Both methods were "standing unilateral bench presses" with the dominant arm, using a functional electromechanical dynamometer. The variable analysed was the mean of the three overhead throws. Ball velocity was measured with a radar (Stalker ATS). The statistical analysis was performed using ANOVA with repeated measures. No significant differences were found for either method (variable resistance intra-repetition: p = 0.194, isometry: p = 0.596). Regarding the individual responses, the analysis showed that 86% of the sample increased throwing velocity with the variable resistance intra-repetition method, while 93% of the sample increased throwing velocity with the isometric method. Both the variable intra-repetition resistance and isometric methods show improvements in ball velocity in female handball players. However, the authors recommend checking individual responses, since the results obtained were influenced by the short rest interval between the pre-activation and the experimental sets.
Background: The purpose of this systematic review was to determine the effect of antioxidant consumption on markers of oxidative stress and muscle damage after performing a muscle strength exercise. Methods: The Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) statements were followed. Four databases were used: Scopus, PubMed, WOS and SportDiscus. Methodological quality was assessed using the PEDro scale. Results: A total of 1709 articles were retrieved and following duplicate removal and application of exclusion criteria seven articles were reviewed. Supplementation with pomegranate juice alleviates oxidative stress, taurine reduces muscle damage, melatonin protects the skeletal muscles, blueberries decrease oxidation and oats mitigate muscle damage. Conclusions: Acute administration of antioxidants immediately before or during an exercise session can have beneficial effects, such as delay of fatigue and a reduction in the recovery period. Administration of antioxidant susbtances may reduce muscle damage and oxidative stress markers.
Jump performance is related to the ability of lower limb muscles to produce power during the push-off phase. However, it is not known if the power associated with the action of active and passive elements of the lower limb muscles change significantly in jumps with positive and negative loads. In this study, the power associated with the action of passive and active components of lower limb muscles as a whole in squat jumps (SJ) with increase and decrease in the external load is analyzed Fourteen trained male subjects (22.5 ± 2.1 years; 176.5 ± 5.4 cm; 75.8 ± 5.8 kg; BMI 24.3 ± 1.8) performed SJ on a force plate. A functional electromechanical dynamometer (FEMD) system was used to change the external load in a range of −30 to +30% of the subject’s body weight. A model comprising a mass, a spring, an active element, and a damper was used. We applied an optimization principle to determine power in center of mass (CoM) (ptot), the powers associated with active element (pact), damper (pƔ), and spring (pk) during the push-off phase. Significant differences between loading conditions for each variable were tested by repeated-measures one-way ANOVA with Bonferroni post hoc analysis, p < 0.05. Shapes of the average curves for instantaneous variation of pact, pƔ, pk, and ptot during push-off with positive loads were closer to 0% than with negative loads. As the load increased, maximum values of ptot, pƔ, and pk decreased. Only with a negative load of −30% did ptot increase significantly, this was not accompanied by changes in pact, pƔ, and pk. The load of one’s own body provides conditions for develop high pact peaks, although the maximum ptot is not achieved in that condition. The increase in negative loads produces a significant increase in ptot, but not in pact and can be interpreted as a situation in which the power delivered to the system by the action of active components is better used. The SJ with positive load, although more similar to the instantaneous changes that occur to the SJ with body weight are not gestures where high power is developed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.