BackgroundInternational and national travelling has made the rapid spread of infectious diseases possible. Little information is available on the role of major traffic hubs, such as airports, in the transmission of respiratory infections, including seasonal influenza and a pandemic threat. We investigated the presence of respiratory viruses in the passenger environment of a major airport in order to identify risk points and guide measures to minimize transmission.MethodsSurface and air samples were collected weekly at three different time points during the peak period of seasonal influenza in 2015–16 in Finland. Swabs from surface samples, and air samples were tested by real-time PCR for influenza A and B viruses, respiratory syncytial virus, adenovirus, rhinovirus and coronaviruses (229E, HKU1, NL63 and OC43).ResultsNucleic acid of at least one respiratory virus was detected in 9 out of 90 (10%) surface samples, including: a plastic toy dog in the children’s playground (2/3 swabs, 67%); hand-carried luggage trays at the security check area (4/8, 50%); the buttons of the payment terminal at the pharmacy (1/2, 50%); the handrails of stairs (1/7, 14%); and the passenger side desk and divider glass at a passport control point (1/3, 33%). Among the 10 respiratory virus findings at various sites, the viruses identified were: rhinovirus (4/10, 40%, from surfaces); coronavirus (3/10, 30%, from surfaces); adenovirus (2/10, 20%, 1 air sample, 1 surface sample); influenza A (1/10, 10%, surface sample).ConclusionsDetection of pathogen viral nucleic acids indicates respiratory viral surface contamination at multiple sites associated with high touch rates, and suggests a potential risk in the identified airport sites. Of the surfaces tested, plastic security screening trays appeared to pose the highest potential risk, and handling these is almost inevitable for all embarking passengers.
The exposure of workers in the near-wake region due to a recirculating airflow was studied experimentally and numerically. A mannequin was installed in an open-ended tunnel and tracer gas was released at several locations downstream to determine the size and location of the reverse flow region. The contaminant transport into the breathing zone was found to depend strongly on the location of the release point. The airflow field was also determined numerically assuming a steady flow and using the standard k-epsilon turbulence model. After calculating the turbulent airflow field, a large number of submicrometre particles were released in different locations downstream of the mannequin to simulate the transport of gaseous contaminants. Although this method does not provide actual exposures, it does predict the tendencies in exposure variations due to different release points quite satisfactorily.
Background The shortage of FFP2 and FFP3 respirators posed a serious threat to the operation of the healthcare system at the onset of the COVID-19 pandemic. Aim Our aim was to develop and validate a large-scale facility that uses hydrogen peroxide vapour for the decontamination of used respirators. Methods A multidisciplinary and multisectoral ad hoc group of experts representing various organisations was assembled to implement the collection and transport of used FFP2 and FFP3 respirators from hospitals covering 86% of the Finnish population. A large-scale decontamination facility using hydrogen peroxide vapour was designed and constructed. Microbiological tests were used to confirm efficacy of hydrogen peroxide vapour decontamination together with a test to assess the effect of decontamination on the filtering efficacy and fit of respirators. Bacterial and fungal growth in stored respirators was determined by standard methods. Results Large-scale hydrogen peroxide vapour decontamination of a range of FFP2 and FFP3 respirator models effectively reduced the recovery of biological indicators: Geobacillus stearothermophilus and Bacillus atrophaeus spores, as well as model virus bacteriophage MS2. The filtering efficacy and facial fit after hydrogen peroxide vapour decontamination were not affected by the process. Microbial growth in the hydrogen peroxide vapour-treated respirators indicated appropriate microbial cleanliness. Conclusions Large-scale hydrogen peroxide vapour decontamination was validated. After effective decontamination, no significant changes in the key properties of the respirators were detected. European Union regulations should incorporate a facilitated pathway to allow reuse of appropriately decontaminated respirators in a severe pandemic when unused respirators are not available.
A simple unipolar positive corona charger was constructed and tested with five different medical face mask materials. Charging of particles significantly increased the filtration efficiency of each of the tested face mask against submicron particles. On the average, the increase in the efficiency was from 58 % to 93 % for 0.3 µm size particles. This improvement was achieved with practically insignificant increase in the pressure drop showing that there are possibilities to fully exploit the potential of electret materials. However, the corona discharge generates ozone which is an issue that needs to be taken into consideration. The results are important when developing efficient protective solutions against airborne threats.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.