Because of its relatively low sensitivity the [(99m)Tc]-sestamibi scan is of limited help in the exploration of uraemic patients with severe secondary hyperparathyroidism before a first surgical PTx. However, it is very useful in locating the remaining parathyroid gland(s) in case of reoperation. The novel calcitriol inhibition test of [(99m)Tc]-sestamibi uptake could help to better distinguish parathyroid glands with non-suppressible, autonomous activity from glands whose activity might be amenable to long-term suppression.
The usefulness of technetium-99m-sestamibi (99mTc-MIBI) in patients with secondary hyperparathyroidism on haemodialysis was assessed. We studied 33 patients with parathyroid scintigraphy with i.v. (99mTc-MIBI). Static images in a scintillation camera were taken at 15 and 120 min after the injection. With P x Ca<80, we performed an inhibition test with calcitriol i.v. 2 microg, three times a week, for 2 weeks. The MIBI study and assessment of intact parathyroid hormone (iPTH) were performed before (baseline study) and after inhibition. A 'focal positive study' corresponded to one or more areas of abnormal hypercaptation in relation to surrounding thyroid tissue seen in early images and persisting in later images, and a 'negative study' did not correspond to the previous image. In the baseline study, iPTH in the positive MIBI group was significantly greater than in the negative group. Eight positive MIBI patients had a bone biopsy; six corresponded to severe osteitis fibrosa and two to mild osteitis fibrosa. In the negative MIBI group, four of the six patients who had bone biopsy had mild forms of osteitis fibrosa (Fisher=0.03); the other two had low turnover forms. A positive inhibition test was defined when the basal uptake disappeared after calcitriol administration. In these patients, we observed a significant decrease of iPTH, not observed in the negative inhibition test. In 10 patients who had been parathyroidectomized, those with alpha positive basal MIBI result had a nodular parathyroid hyperplasia. We conclude that a scintigraphic parathyroid study with 99mTc-MIBI showed a good correlation with functional parathyroid status. With the same inhibition test, only some glands were inhibited, suggesting that this could be the expression of different vitamin D receptor densities in inhibited glands and/or a different kind of proliferation in those glands. This test would be of value in functional studies when a therapeutic decision must be made.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.