Background This prospective multicenter study funded by the DEGUM assesses the diagnostic accuracy of standardized contrast-enhanced ultrasound (CEUS) for the noninvasive diagnosis of hepatocellular carcinoma (HCC) in high-risk patients.
Methods Patients at high risk for HCC with a histologically proven focal liver lesion on B-mode ultrasound were recruited prospectively in a multicenter approach. Clinical and imaging data were entered via online entry forms. The diagnostic accuracies for the noninvasive diagnosis of HCC were compared for the conventional interpretation of standardized CEUS at the time of the examination (= CEUS on-site) and the two CEUS algorithms ESCULAP (Erlanger Synopsis for Contrast-enhanced Ultrasound for Liver lesion Assessment in Patients at risk) and CEUS LI-RADS (Contrast-Enhanced UltraSound Liver Imaging Reporting and Data System).
Results 321 patients were recruited in 43 centers; 299 (93.1 %) had liver cirrhosis. The diagnosis according to histology was HCC in 256 cases, and intrahepatic cholangiocarcinoma (iCCA) in 23 cases. In the subgroup of cirrhotic patients (n = 299), the highest sensitivity for the diagnosis of HCC was achieved with the CEUS algorithm ESCULAP (94.2 %) and CEUS on-site (90.9 %). The lowest sensitivity was reached with the CEUS LI-RADS algorithm (64 %; p < 0.001). However, the specificity of CEUS LI-RADS (78.9 %) was superior to that of ESCULAP (50.9 %) and CEUS on-site (64.9 %; p < 0.001). At the same time, the negative predictive value (NPV) of CEUS LI-RADS was significantly inferior to that of ESCULAP (34.1 % vs. 67.4 %; p < 0.001) and CEUS on-site (62.7 %; p < 0.001). The positive predictive values of all modalities were high (around 90 %), with the best results seen for CEUS LI-RADS and CEUS on-site.
Conclusion This is the first multicenter, prospective comparison of standardized CEUS and the recently developed CEUS-based algorithms in histologically proven liver lesions in cirrhotic patients. Our results reaffirm the excellent diagnostic accuracy of CEUS for the noninvasive diagnosis of HCC in high-risk patients. However, on-site diagnosis by an experienced examiner achieves an almost equal diagnostic accuracy compared to CEUS-based diagnostic algorithms.
and the Bornavirus-Encephalitis Study Group Objective: The number of diagnosed fatal encephalitis cases in humans caused by the classical Borna disease virus (BoDV-1) has been increasing, ever since it was proved that BoDV-1 can cause human infections. However, awareness of this entity is low, and a specific imaging pattern has not yet been identified. We therefore provide the first comprehensive description of the morphology of human BoDV-1 encephalitis, with histopathological verification of imaging abnormalities. Methods: In an institutional review board-approved multicenter study, we carried out a retrospective analysis of 55 magnetic resonance imaging (MRI) examinations of 19 patients with confirmed BoDV-1 encephalitis. Fifty brain regions were analyzed systematically (T1w, T2w, T2*w, T1w + Gd, and DWI), in order to discern a specific pattern of inflammation. Histopathological analysis of 25 locations in one patient served as correlation for MRI abnormalities. Results: Baseline imaging, acquired at a mean of 11 AE 10 days after symptom onset, in addition to follow-up scans of 16 patients, revealed characteristic T2 hyperintensities with a predilection for the head of the caudate nucleus, insula, and cortical spread to the limbic system, whereas the occipital lobes and cerebellar hemispheres were unaffected. This gradient was confirmed by histology. Nine patients (47.4%) developed T1 hyperintensities of the basal ganglia, corresponding to accumulated lipid phagocytes on histology and typical for late-stage necrosis. Interpretation: BoDV-1 encephalitis shows a distinct pattern of inflammation in both the early and late stages of the disease. Its appearance can mimic sporadic Creutzfeldt-Jakob disease on MRI and should be considered a differential diagnosis in the case of atypical clinical presentation.
A combination of CEUS with perfusion imaging enables critical assessment of successful treatment after percutaneous interventional procedures for a malignant liver lesion.
CEUS and MRI with liver-specific contrast media are very reliable and of equal informative value in the characterization of focal liver lesions. The number of false-negative results can be decreased using a combination of the two methods.
The external perfusion software (VueBox™) for contrast-enhanced ultrasound (CEUS), enables the quantitative analysis of micro-vascularization within non-cystic lesions in terms of characterization and detection. This review summarizes our work about parathyroid gland, thyroid gland, liver, prostate and other tissues as well as original studies in the use of parametric perfusion imaging. Useful perfusion parameters are introduced.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.