Obese patients with end-stage renal disease (ESRD) are often excluded from kidney transplantation due to concerns about surgical site infections. To reduce infections, we developed a robotic kidney transplantation method for obese recipients. From June 2009-December 2011, a prospective cohort of 39 obese patients underwent robotic kidney transplantation at a single center. The outcomes of patients with at least six months of follow-up (n=28) were compared to a frequency-matched retrospective cohort of obese patients who underwent open kidney transplantation from 2004-2009 (n=28). The 28 robotic patients were predominately African-American (46.4%) or Hispanic (35.7%), with a mean age of 47.9±10.7 years, similar to the control group. BMI in the robotic group was 42.6±7.8 kg/m2 compared to 38.1±5.4 kg/m2 in the control group (p=0.02). There were no surgical site infections in the robotic group (0/28), while 28.6% (8/28) in the control group developed an infection (p=0.004). Six-month creatinine (1.5±0.4 vs.1.6±0.6 mg/dL; p=0.47), and patient and graft survival (100%) were comparable between the two groups. Outcomes following robotic surgery compared favorably to conventional transplantation. Robotic surgery may therefore enable obese patients with ESRD to access kidney transplantation and may thereby reduce health disparities in groups with a high prevalence of obesity and ESRD.
Kidney transplantation in morbidly obese patients can be technically demanding. Furthermore, morbidly obese patients experience a high rate of wound infections and related complications, which mostly result from the longer length and extent of the incision. These complications can be avoided through minimally invasive surgery; however, conventional laparoscopic instruments are unsuitable for the safe performance of a kidney transplant in morbidly obese patients. Herein, we report the first minimally invasive, total robotic kidney transplant in a morbidly obese patient. A left, deceased donor kidney was transplanted into a 29-year-old woman with a body mass index (BMI) of 41 kg/m 2 who had been on hemodialysis for 5 years. The operation was performed intraabdominally using the DaVinci Robotic Surgical System with 4 trocars and a 7 cm midline incision. The operative time was 223 min, and the blood loss was less than 50 cc. The kidney had immediate graft function. No perioperative complications were observed, and the patient was discharged on postoperative day 5 with normal kidney function. Minimally invasive access and robotic technology facilitated the safe performance of a successful kidney transplant in a morbidly obese patient.
Despite increased rejection rates, graft and patient survivals indicate that desensitization of positive crossmatch patients is a reasonable alternative for a sensitized patient who could potentially wait 10 or more years for a suitable cadaveric kidney.
Summary
Recent advances in robotic surgical technology have enabled application to complex surgical procedures. Following extensive institutional experience with major robotic liver resections, we determined that it was safe to apply this technology to right lobe donor hepatectomy (RLDH). The procedure was performed using the Da Vinci Robotic Surgical System, in an entirely minimally invasive fashion, during which the liver graft was safely extracted through a limited lower abdominal incision. Both donor and recipient recovered well, without acute complications. To our knowledge, this is the first case reported in the literature. The technical feasibility of this minimally invasive approach is demonstrated, exemplifying the novel exciting opportunities offered by robotic technology.
Background: One of the perceived major drawbacks of minimally invasive techniques has always been its cost. This is especially true for the robotic approach and is one of the main reasons that has prevented its wider acceptance among hospitals and surgeons. The aim of our study was to evaluate the clinical outcomes and economic impact of robotic and open liver surgery in a single institution.Methods: Sixty-eight robotic and 55 open hepatectomies were performed at our institution between January 1, 2009 and December 31, 2013. Demographics, perioperative data, and postoperative outcomes were collected and compared between the two groups. An independent company performed the financial analysis. The economic parameters comprised direct variable costs, direct fixed costs, and indirect costs.Results: Mean estimated blood loss was significantly less in the robotic group (438 versus 727.8 mL; P = .038). Overall morbidity was significantly lower in the robotic group (22% versus 40%; P = .047). Clavien III/IV complications were also lower, with 4.4% in the robotic versus 16.3% in the open group (P = .043). The length of stay in the intensive care unit (ICU) was shorter for patients who underwent a robotic procedure (2.1 versus 3.3 days; P = .004). The average total cost, including readmissions, was $37,518 for robotic surgery and $41,948 for open technique.Conclusions: Robotic liver resections had less overall morbidity, ICU, and hospital stay. This translates into decreased average costs for robotic surgery. These procedures are financially comparable to open resections and do not represent a financial burden to the hospital.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.