A simple approach was developed that calculates the output factors and tissue maximum ratio of an asymmetric field at any point within the open field, and specifically both at the central axis (when the jaws do not shadow it) and at the effective center of the open field, using the existing tables for symmetric fields and the multidepth profile information for the largest available field size (either open or with a wedge present). Day's method was adapted to calculate the effective values of the usual field-size-dependent parameters. This approach makes these parameters also dependent on the location of the calculation point relative to the field edges in an asymmetric field. This algorithm was tested by comparing its predictions with measurements of asymmetric and half blocked fields, with and without wedges, in a water phantom at different depths and off-axis distances. The agreement between calculated and measured dose rate is within 1%-3% even in highly asymmetric fields for both 6- and 18-MV photons.
Purpose: Recent advancements in radiologic imaging (IGRT) have acquired 4D anatomic data permitting characterization of organ motion towards improving radiotherapy delivery. For radiation oncology patients, images illustrating temporal migration or tumor motion as a result of innate biological function can provide significant benefit towards improving target accuracy and minimizing healthy tissue dose. This study examines the utility of the Perspecta Spatial 3D system (Actuality Systems Inc) to display dynamic 3D data in comparison to flat panel 2D displays. Method and Materials: The AqSim (Philips Medical Systems) CT scanner was used to obtain scans of a patient with lung cancer, and entered into the Pinnacle3 treatment planning system (Philips Medical Systems). A clearly delineated lung tumor was contoured in each pertinent CT slice. Ten scans (64 slices each) were obtained during the breathing cycle. Data were viewed side‐by‐side on a flat panel display and the Perspecta 3D system for comparison. Results: The Perspecta display permitted simultaneous visualization of ten CT scans at ∼ 1 Hz per dataset which was similar to the natural breathing rate during image acquisition. Optimal static beam orientation for dynamic target coverage and OAR avoidance was more easily accomplished on the Perspecta than on the 2D display. Conclusion: The 3D Perspecta display successfully depicted anatomic motion, clearly indicating tumor and OAR motion. In comparison to the 2D flat panel display, the Perspecta display permitted the radiation oncology team to readily visualize the temporal nature of lung tumor location for consideration during treatment planning. This application could play an important role in defining and displaying 4D patient data, which was previously relegated to predominantly 2D RTP systems. Furthermore, breath‐hold and coached breathing techniques may be quantitatively evaluated using this method. Conflict of Interest Statement: Actuality Systems Inc. provided the 3D display used in this study.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.