The aim of the experiments was to check the feasibility of pulmonary perfusion imaging by functional electrical impedance tomography (EIT) and to compare the EIT findings with electron beam computed tomography (EBCT) scans. In three pigs, a Swan-Ganz catheter was positioned in a pulmonary artery branch and hypertonic saline solution or a radiographic contrast agent were administered as boli through the distal or proximal openings of the catheter. During the administration through the proximal opening, the balloon at the tip of the catheter was either deflated or inflated. The latter case represented a perfusion defect. The series of EIT scans of the momentary distribution of electrical impedance within the chest were obtained during each saline bolus administration at a rate of 13/s. EBCT scans were acquired at a rate of 3.3/s during bolus administrations of the radiopaque contrast material under the same steady-state conditions. The EIT data were used to generate local time-impedance curves and functional EIT images showing the perfusion of a small lung region, both lungs with a perfusion defect and complete both lungs during bolus administration through the distal and proximal catheter opening with an inflated or deflated balloon, respectively. The results indicate that EIT imaging of lung perfusion is feasible when an electrical impedance contrast agent is used.
The CNAP monitor showed an acceptable agreement and was interchangeable with invasive pressure monitoring for MAP during normotensive conditions. During induction of anaesthesia and when the AP was low, the agreement was less good and interchangeability was not achieved. These results suggest that CNAP is not statistically equivalent to invasive monitoring during all periods of anaesthesia but may be a useful additional AP monitor.
A dynamic viscosity correction of TD improves the accuracy of FRC determinations by MBNW considerably, when gas concentrations are measured in a sidestream. If dynamic TD correction cannot be performed, the use of constant TDmean might be suitable. However, in patient measurements this can cause an FRC underestimation of up to 13%.
Economic pressures are forcing German hospitals to take measures to secure the cost effectiveness of medical care. Surgical facilities are particularly affected as a high-cost segment. As a consequence hospital operators and administrators have begun to hire surgical facility (OR) managers whose task it is to implement efficiency-oriented steps and reorganization measures aimed at increasing productivity and profitability of the surgical services. The OR manager is confronted with high expectations in a complex environment full of potential conflicts. With this in mind, the following article defines and comments on the most important aspects of OR managerial duties and responsibilities. The authors are experienced in OR management and are able to give the reader not only the theoretical fundamentals but also recommendations and guidelines which are particularly valuable to those contemplating a career as OR manager.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.