This study compares the efficacy of porcine intestinal submucosa (SIS) patch graft versus SIS-tube graft in esophageal replacement, using a novel esophageal regeneration model. Clinical function, as well as macroscopic and microscopic morphology were evaluated in both SIS-treated groups. We performed semi-circumferential esophageal excision followed by repair of the defect using either a SIS-patch graft (group I) or segmental esophageal excision followed by a SIS-tube interposition graft (group II) in rats. The 28-day survival rate was significantly different between the SIS-treated groups (100% in group I vs. 0% in group II). Unlike the rats in group II, which died within the first postoperative month due to esophageal dysfunction, all surviving animals in group I resumed a normal solid diet within a few days after surgery, without signs of esophageal dysfunction and gained weight. Barium swallow studies showed no evidence of fistula, significant stenosis or diverticula. No hematological or serum biochemistry abnormalities were found. By day 150 the SIS patch was replaced by esophageal-derived tissues. In the rat model, a patch graft technique using SIS appeared to induce esophageal regrowth and provided an initial and long-term satisfactory function, while a tube-shaped graft technique using SIS was unsuccessful.
Gastrointestinal (GI) bleeding is a common clinical condition that is increasingly seen in an aging population and frequently requires hospitalization and intervention, with significant morbidity and mortality. Obscure GI bleeding (OGIB) is defined as loss of blood with no source identified after upper endoscopy and colonoscopy. Whether an obscure site of bleeding is clinically evident or silent, it constitutes a diagnostic and therapeutic challenge for the clinician. Gastroenterology and radiology provide the essential diagnostic tools used to evaluate suspected OGIB, each with its strengths and weaknesses. Small bowel series and conventional enteroclysis have a limited role in OGIB. Computed tomographic (CT) enterography and CT enteroclysis are noninvasive techniques with promising results in evaluation of small bowel disease and silent OGIB. CT angiography is a useful triaging tool for diagnosing or excluding active GI hemorrhage, localizing the site of bleeding, and guiding subsequent treatment. Tagged red blood cell scanning is the most sensitive technique for detection of active GI bleeding and allows imaging over a prolonged period, making it useful for detecting intermittent bleeding. Capsule endoscopy has emerged as an important tool for investigating OGIB, but it may soon have competition from double-balloon enteroscopy, a diagnostic technique that can also facilitate therapy.
Porcine small intestinal submucosa (SIS) is a cell-free collagen matrix that has demonstrated its ability as scaffold material for constructive remodeling of damaged or missing tissue. The purpose of this study was to evaluate the morphology and function of esophagoplasty in rat using a porcine SIS scaffold for the repair of a semi-circumferential defect in the cervical or in the abdominal esophagus. Sixty-seven rats underwent surgical excision of the anterior wall either of the cervical or of the abdominal esophagus and subsequent repair of the defect with an SIS patch graft. Outcomes of weight gain, signs of dysphagia, hematological and serum chemistry parameters, and barium swallow studies were used to assess the progress of healing and function over a 150-day time period. The grafts were studied for gross changes and histology at predetermined time points. Ninety-four percent of the SIS-treated rats survived, showing no significant differences in survival rate between groups. The grafted animals did well, without signs of dysphagia, and gaining weight. Barium swallow studies showed no evidence of fistula, significant stenosis, or diverticula. No hematological or serum biochemistry abnormalities were found. By 150 days, the SIS graft was replaced with esophageal-derived tissues. Specimens were completely lined by keratinized stratified squamous epithelium and showed complete regeneration of muscle fibers and scarce immunoreactivity for nerve. In the rat model, a patch graft technique using porcine SIS appears to induce esophageal regrowth either in cervical and abdominal esophagus. The repair mechanism occurred through a regenerative healing process.
ObjectivesTo review the most common disorders depicted with conventional videodefecography, and to compare the defecographic abnormalities between symptomatic patients according to their gender and age.MethodsConventional videodefecography studies of 300 patients (24 men, 266 women; mean age – 57.7) performed in a 32-month period were reviewed for the following parameters: anorectal angle, movement of the pelvic floor, intussusceptions, incontinence and rectocele. The results were analyzed using the chi-square test.ResultsNormal findings were observed in 16.7% men and 7.5% women. In women, the most frequent pathological findings were rectocele (62%), descending perineum syndrome (42.8%), intussusceptions (33.8%), incontinence (10.5%), dyskinetic puborectalis syndrome (9.4%) and rectal prolapse (4.5%); in men the most frequent pathology was the dyskinetic puborectalis syndrome (37.5%). This syndrome is more likely in men than in women (p = 0.01; OR 5.78); descending perineum syndrome (p = 0.027; OR 2.8) is more likely to occur in women.Women with perineal descent younger than 50 years frequently present an increased descent during evacuation (81.8%), while those older than 50 years already have a low pelvic floor during rest (60.3%) (p < 0.001; OR 6.8), with little change in evacuation.ConclusionVideodefecographic findings vary with age and gender.
Background: To determine the accuracy of computed tomography performed with a water enema application (WE-CT) in the local staging of low colorectal neoplasms and to compare the results with those of transrectal ultrasonography (TRUS). Methods: Forty patients with low colorectal tumors were evaluated prospectively by CT with the simultaneous administration of a lukewarm rectal enema (0.5-1.5 L). Thin slices (5 mm) and intravenous application of iodinated contrast media were routinely used. TRUS was performed in 18 patients. Tumor size, location, and staging according to the TNM classification of the UICC were registered. Tumors were classified as õT3 (T1 or T2) or as T3 or T4. For staging peritumoral lymph node metastases on WE-CT, two criteria of positivity were tested: N/ if at least one peritumoral node ¢5 mm in diameter was seen (reading A); N/ if at least one peritumoral node ¢5 mm or three peritumoral nodes õ5 mm were identified (reading B). Results: For the tumor staging, WE-CT showed a sensitivity of 90%, a specificity of 73%, a positive predictive value (PPV) of 90%, a negative predictive value (NPV) of 73%, and an accuracy of 85%. For TRUS, the results were sensitivity of 73%, specificity of 29%, PPV of 62%, NPV of 40%, and an accuracy of 39%. Concerning nodal staging with WE-CT, results were superior when reading A was used: sensitivity Å 84%, specificity Å 83%, PPV Å 73%, NPV Å 91%, and accuracy Å 84%. TRUS showed a sensitivity of 29%, specificity of 100%, PPV of 100%, NPV of 67%, and an accuracy of 71%.Correspondence to: F. Caseiro-Alves Conclusion: WE-CT is a reliable technique for the local staging of low colorectal tumors that can be superior to TRUS. For diagnosis of peritumoral metastatic lymph nodes on WE-CT, the 5-mm diameter cutoff value is the most appropriate size criterion.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.