BackgroundThis study evaluated an automated inverse treatment planning algorithm, Pinnacle Auto-Planning (AP), and compared automatically generated plans with historical plans in a large cohort of head and neck cancer patients.MethodsFifty consecutive patients treated with volumetric modulated arc therapy (Eclipse, Varian Medical System, Palo Alto, CA) for head and neck were re-planned with AP version 9.10. Only one single cycle of plan optimization using one single template was allowed for AP. The dose to the planning target volumes (PTV’s; 3–4 dose levels), the organs at risk (OAR’s) and the effective working time for planning was evaluated. Additionally, two experienced radiation oncologists blind-reviewed and ranked 10 plans.ResultsDose coverage and dose homogeneity of the PTV were significantly improved with AP, however manually optimized plans showed significantly improved dose conformity. The mean dose to the parotid glands, oral mucosa, swallowing muscles, dorsal neck tissue and maximal dose to the spinal cord were significantly reduced with AP. In 64 % of the plans, the mean dose to any OAR (spinal cord excluded) was reduced by >20 % with AP in comparison to the manually optimized plans. In 12 % of the plans, the manually optimized plans showed reduced doses by >20 % in at least one OAR. The experienced radiation oncologists preferred the AP plan and the clinical plan in 80 and 20 % of the cases, respectively. The average effective working time was 3.8 min ± 1.1 min in comparison to 48.5 min ± 6.0 min using AP compared to the manually optimized plans, respectively.ConclusionThe evaluated automated planning algorithm achieved highly consistent and significantly improved treatment plans with potentially clinically relevant OAR sparing by >20 % in 64 % of the cases. The effective working time was substantially reduced with Auto-Planning.
BackgroundAutomated treatment planning and/or optimization systems (ATPS) are in the process of broad clinical implementation aiming at reducing inter-planner variability, reducing the planning time allocated for the optimization process and improving plan quality. Five different ATPS used clinically were evaluated for advanced head and neck cancer (HNC).MethodsThree radiation oncology departments compared 5 different ATPS: 1) Automatic Interactive Optimizer (AIO) in combination with RapidArc (in-house developed and Varian Medical Systems); 2) Auto-Planning (AP) (Philips Radiation Oncology Systems); 3) RapidPlan version 13.6 (RP1) with HNC model from University Hospital A (Varian Medical Systems, Palo Alto, USA); 4) RapidPlan version 13.7 (RP2) combined with scripting for automated setup of fields with HNC model from University Hospital B; 5) Raystation multicriteria optimization algorithm version 5 (RS) (Laboratories AB, Stockholm, Sweden). Eight randomly selected HNC cases from institution A and 8 from institution B were used. PTV coverage, mean and maximum dose to the organs at risk and effective planning time were compared. Ranking was done based on 3 Gy increments for the parallel organs.ResultsAll planning systems achieved the hard dose constraints for the PTVs and serial organs for all patients. Overall, AP achieved the best ranking for the parallel organs followed by RS, AIO, RP2 and RP1. The oral cavity mean dose was the lowest for RS (31.3 ± 17.6 Gy), followed by AP (33.8 ± 17.8 Gy), RP1 (34.1 ± 16.7 Gy), AIO (36.1 ± 16.8 Gy) and RP2 (36.3 ± 16.2 Gy). The submandibular glands mean dose was 33.6 ± 10.8 Gy (AP), 35.2 ± 8.4 Gy (AIO), 35.5 ± 9.3 Gy (RP2), 36.9 ± 7.6 Gy (RS) and 38.2 ± 7.0 Gy (RP1). The average effective planning working time was substantially different between the five ATPS (in minutes): < 2 ± 1 for AIO and RP2, 5 ± 1 for AP, 15 ± 2 for RP1 and 340 ± 48 for RS, respectively.ConclusionsAll ATPS were able to achieve all planning DVH constraints and the effective working time was kept bellow 20 min for each ATPS except for RS. For the parallel organs, AP performed the best, although the differences were small.
Background: Online adaptive radiotherapy is intended to prevent plan degradation caused by inter-fractional tumor volume and shape changes, but time limitations make online re-planning challenging. The aim of this study was to compare the quality of online-adapted plans to their respective reference treatment plans. Methods: Fifty-two patients treated on a ViewRay MRIdian Linac were included in this retrospective study. In total 238 online-adapted plans were analyzed, which were optimized with either changing of the segment weights (n = 85) or full re-optimization (n = 153). Five different treatment sites were evaluated: prostate, abdomen, liver, lung and pelvis. Dosimetric parameters of gross tumor volume (GTV), planning target volume (PTV), 2 cm ring around the PTV and organs at risk (OARs) were considered. The Wilcoxon signed-rank test was used to assess differences between online-adapted and reference treatment plans, p < 0.05 was considered significant. Results: The average duration of the online adaptation, consisting of contour editing, plan optimization and quality assurance (QA), was 24 ± 6 min. The GTV was slightly larger (average ± SD: 1.9% ± 9.0%) in the adapted plans than in the reference plans (p < 0.001). GTV-D 95% exhibited no significant changes when considering all plans, but GTV-D 2% increased by 0.40% ± 1.5% on average (p < 0.001). There was a very small yet significant decrease in GTVcoverage for the abdomen plans. The ring D mean increased on average by 1.0% ± 3.6% considering all plans (p < 0.001). There was a significant reduction of the dose to the rectum of 4.7% ± 16% on average (p < 0.001) for prostate plans. Conclusions: Dosimetric quality of online-adapted plans was comparable to reference treatment plans and OAR dose was either comparable or decreased, depending on treatment site. However, dose spillage was slightly increased.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.