Examples are given which prove the ICARUS detector quality through relevant physics measurements. We study the µ decay energy spectrum from a sample of stopping µ events acquired during the test run of the ICARUS T600 detector. This detector allows the spatial reconstruction of the events with fine granularity, hence, the precise measurement of the range and dE/dx of the µ with high sampling rate. This information is used to compute the calibration factors needed for the full calorimetric reconstruction of the events. The Michel ρ parameter is then measured by comparison of the experimental and Monte Carlo simulated µ decay spectra, obtaining ρ = 0.72 ± 0.06 (stat.) ± 0.08 (syst.). The energy resolution for electrons below ∼ 50 MeV is finally extracted from the simulated sample, obtaining (E e meas − E e MC )/E e M C = 11%/ E [MeV] ⊕ 2%.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.