Ponds on peatlands of the Hudson Bay lowlands (HBLs) are complex ecosystems in which the fluxes to the atmosphere of CH4 and CC2 were controlled by interacting physical and biological factors. This resulted in strong diel variations of both dissolved gas concentrations and gas fluxes to the atmosphere, necessitating frequent sampling on a 24‐hour schedule to enable accurate estimates of daily fluxes. Ponds at three sites on the HBL were constant net sources of CH4 and CO2 to the atmosphere at mean rates of 110–180 mg CH4 m−2 d−1 and 3700–11,000 mg CO2 m−2 d−1. Rates peaked in August and September. For CH4 the pond fluxes were 3–30 times higher than adjacent vegetated surfaces. For CO2 the net pond fluxes were similar in magnitude to the vegetated fluxes but the direction of the flux was opposite, toward atmosphere. Even though ponds cover only 8–12% of the HBL area, they accounted for 30% of its total CH4 flux to the atmosphere. There is some circumstantial evidence that the ponds are being formed by decomposition of the underlying peat and that this decomposition is being stimulated by the activity of N2 fixing cyanobacteria that grow in mats at the peat‐water interface. The fact that the gas fluxes from the ponds were so different from the surrounding vegetated surfaces means that any change in the ratio of pond to vegetated area, as may occur in response to climate change, would affect the total HBL fluxes.
Two-dimensional phased arrays for high frequency (>30 MHz) ultrasonic imaging are difficult to construct using conventional piezoelectric technology. A promising alternative involves optical detection of ultrasound, where the array element size is defined by the focal spot of a laser beam. Element size and spacing on the order of a few microns are easily achieved, suitable for imaging at frequencies exceeding 100 MHz. We have previously shown images made from a receive-only, two-dimensional optoacoustic array operating at 10 to 50 MHz. The main drawback of optical detection has been poor sensitivity when compared with piezoelectric detection. In this paper, we explore a different form of optical detection demonstrating improved sensitivity and offering a potentially simple method for constructing two-dimensional arrays. Results from a simple experiment using an etalon sensor confirm that the sensitivity of etalon detection is comparable with piezoelectric detection. This paper concludes with a proposal for a high frequency optoacoustic array system using an etalon.
Contrast agents, such as bubbles, are used in ultrasound to enhance backscatter from blood. To increase contrast between these agents and tissue, nonlinear methods such as harmonic imaging can be used. Contrast is limited, however, by tissue second harmonic signals. We show that a major source of this signal is nonlinear propagation through tissue. In addition, we present methods to suppress this second harmonic generation. One simple approach is to decrease the f/number of the imaging system. Simulations show that doubling the size of the array, while keeping total power output constant, decreases propagating second harmonic generation. A second approach uses active noise cancellation to suppress second harmonic generation. A specific method, the harmonic cancellation system (HCS), is developed and presented as an example. In simulations, HCS decreased second harmonic generation by over 30 dB. Using such methods, contrast can be improved between tissue and bubbles in harmonic imaging.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.