AimTo characterize and compare total lung capacity (TLC) measured by plethysmography with high-resolution computed tomography (HRCT), and to identify variables that predict the difference between the two modalities.MethodsFifty-nine consecutive patients referred for the evaluation of COPD were retrospectively reviewed. Patients underwent full pulmonary function testing and HRCT within 3 months. TLC was obtained by plethysmography as per American Thoracic Society/European Respiratory Society standards and by HRCT using custom software on 0.75 and 5 mm thick contiguous slices performed at full inspiration (TLC).ResultsTLC measured by plethysmography correlated with TLC measured by inspiratory HRCT (r = 0.92, P < 0.01). TLC measured by plethysmography was larger than that determined by inspiratory HRCT in most patients (mean of 6.46 ± 1.28 L and 5.34 ± 1.20 L respectively, P < 0.05). TLC measured by both plethysmography and HRCT correlated significantly with indices of airflow obstruction (forced expiratory volume in 1 second/forced vital capacity [FVC] and FVC%), static lung volumes (residual volume, percent predicted [RV%], total lung capacity, percent predicted [TLC%], functional residual capacity, percent predicted [FRC%], and inspiratory capacity, percent predicted), and percent emphysema. TLC by plethysmography and HRCT both demonstrated significant inverse correlations with diffusion impairment. The absolute difference between TLC measured by plethysmography and HRCT increased as RV%, TLC%, and FRC% increased. Gas trapping (RV% and FRC%) independently predicted the difference in TLC between plethysmography and HRCT.ConclusionIn COPD, TLC by plethysmography can be up to 2 L greater than inspiratory HRCT. Gas trapping independently predicts patients for whom TLC by plethysmography differs significantly from HRCT.
Background Infection with the novel severe acute respiratory syndrome coronavirus 2 has been associated with a hypercoagulable state. Emerging data from China and Europe have consistently shown an increased incidence of venous thromboembolism (VTE). We aimed to identify the VTE incidence and early predictors of VTE at our high-volume tertiary care center. Methods We performed a retrospective cohort study of 147 patients who had been admitted to Temple University Hospital with coronavirus disease 2019 (COVID-19) from April 1, 2020 to April 27, 2020. We first identified the VTE (pulmonary embolism [PE] and deep vein thrombosis [DVT]) incidence in our cohort. The VTE and no-VTE groups were compared by univariable analysis for demographics, comorbidities, laboratory data, and treatment outcomes. Subsequently, multivariable logistic regression analysis was performed to identify the early predictors of VTE. Results The 147 patients (20.9% of all admissions) admitted to a designated COVID-19 unit at Temple University Hospital with a high clinical suspicion of acute VTE had undergone testing for VTE using computed tomography pulmonary angiography and/or extremity venous duplex ultrasonography. The overall incidence of VTE was 17% (25 of 147). Of the 25 patients, 16 had had acute PE, 14 had had acute DVT, and 5 had had both PE and DVT. The need for invasive mechanical ventilation (adjusted odds ratio, 3.19; 95% confidence interval, 1.07-9.55) and the admission D-dimer level ≥1500 ng/mL (adjusted odds ratio, 3.55; 95% confidence interval, 1.29-9.78) were independent markers associated with VTE. The all-cause mortality in the VTE group was greater than that in the non-VTE group (48% vs 22%; P = .007). Conclusion Our study represents one of the earliest reported from the United States on the incidence rate of VTE in patients with COVID-19. Patients with a high clinical suspicion and the identified risk factors (invasive mechanical ventilation, admission D-dimer level ≥1500 ng/mL) should be considered for early VTE testing. We did not screen all patients admitted for VTE; therefore, the true incidence of VTE could have been underestimated. Our findings require confirmation in future prospective studies.
Increased sputum production in severe COPD is frequently encountered daily and is associated with more respiratory symptoms, worse airflow obstruction, and less emphysema.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.