A new 3D reconstruction scheme, weighted filtered backprojection (WFBP) for multirow spiral CT based on an extension of the two-dimensional SMPR algorithm is described and results are presented. In contrast to other 3D algorithms available, the algorithm makes use of all available data for all pitch values. The algorithm is a FBP algorithm: linear convolution of the parallel data along the row direction followed by a 3D backprojection. Data usage for arbitrary pitch values is maintained through a weighting scheme which takes into account redundant data. If proper row weighting is applied, the image quality is superior to the image quality of the SMPR algorithm.
Cardiac interventional procedures would benefit tremendously from sophisticated three-dimensional image guidance. Such procedures are typically performed with C-arm angiography systems, and tomographic imaging is currently available only by using preprocedural computed tomography (CT) or magnetic resonance imaging (MRI) scans. Recent developments in C-arm CT (Angiographic CT) allow three-dimensional (3-D) imaging of low contrast details with angiography imaging systems for noncardiac applications. We propose a new approach for cardiac imaging that takes advantage of this improved contrast resolution and is based on intravenous contrast injection. The method is an analogue to multisegment reconstruction in cardiac CT adapted to the much slower rotational speed of C-arm CT. Motion of the heart is considered in the reconstruction process by retrospective electrocardiogram (ECG)-gating, using only projections acquired at a similar heart phase. A series of N almost identical rotational acquisitions is performed at different heart phases to obtain a complete data set at a minimum temporal resolution of 1/N of the heart cycle time. First results in simulation, using an experimental phantom, and in preclinical in vivo studies showed that excellent image quality can be achieved.
Advanced bronchial carcinomas by means of perfusion and peak enhancement using dynamic contrast-enhanced multislice CT are characterized. Twenty-four patients with advanced bronchial carcinoma were examined. During breathhold, after injection of a contrast-medium (CM), 25 scans were performed (1 scan/s) at a fixed table position. Density-time curves were evaluated from regions of interest of the whole tumor and high- and low-enhancing tumor areas. Perfusion and peak enhancement were calculated using the maximum-slope method of Miles and compared with size, localization (central or peripheral) and histology. Perfusion of large tumors (> 50 cm3) averaged over both the whole tumor (P = 0.001) and the highest enhancing area (P = 0.003) was significantly lower than that of smaller ones. Independent of size, central carcinomas had a significantly (P = 0.04) lower perfusion (mean 27.9 ml/min/100 g) than peripheral ones (mean 66.5 ml/min/100 g). In contrast, peak enhancement of central and peripheral carcinomas was not significantly different. Between non-small-cell lung cancers and small-cell lung cancers, no significant differences were observed in both parameters. In seven tumors, density increase after CM administration started earlier than in the aorta, indicating considerable blood supply from pulmonary vessels. Tumor perfusion was dependent on tumor size and localization, but not on histology. Furthermore, perfusion CT disclosed blood supply from both pulmonary and/or bronchial vessels in some tumors.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.