The anti-epileptic effect of anterior thalamic DBS may be dependent on stimulation site especially in the anterior to posterior axis. Extensive anatomical variation confounds severely the targeting of ANT. Therefore, direct visualization of the desired target for stimulation is essential for favourable outcome in refractory epilepsy.
BackgroundDeep brain stimulation (DBS) is a minimally invasive and reversible method to treat an increasing number of neurological and psychiatric disorders, including epilepsy. Targeting poorly defined deep structures is based in large degree on stereotactic atlas information, which may be a major source of inconsistent treatment effects.Aim of the studyIn the present study, we aimed to study whether a recently approved target for epilepsy (anterior nucleus of thalamus, ANT) is visualized in clinically established 3 T MRI and whether ANT is delineated using intraoperative microelectrode recording (MER). We have especially focused on individual variation in the location of ANT in stereotactic space. We also aimed to demonstrate the role of individual variation in interpretation of MER data by projecting samples onto AC–PC (anterior and posterior commissure) and ANT-normalized coordinate systems.MethodsDetailed analysis of ANT delineations in 3 T MRI short tau inversion recovery (STIR) images from eight patients undergoing DBS for refractory epilepsy was performed. Coronal and sagittal cross-sectional models of ANT were plotted in the AC–PC coordinate system to study individual variation. A total of 186 MER samples collected from 10 DBS trajectories and 5 patients were analyzed, and the location of each sample was calculated and corrected accordingly to the location of the final DBS electrode and projected to the AC–PC or coordinate system normalized to ANT.ResultsMost of the key structures in the anatomic atlas around ANT (mammillothalamic tract and external medullary lamina) were identified in STIR images allowing visual delineation of ANT. We observed a high degree of anatomical variation in the location of ANT, and the cross-sectional areas overlapped by study patients decreased in a linear fashion with an increasing number of patients. MER information from 10 individual trajectories correlated with STIR signal characteristics by demonstrating a spike-negative zone, presumably white matter layer, at the lateral aspect of ANT in ANT-normalized coordinate system as predicted by STIR images. However, MER information projected to the AC–PC coordinate system was not able to delineate ANT.ConclusionsANT is delineated in 3 T MRI by visualization of a thin white matter lamina between ANT and other nuclear groups that lack spiking activity. Direct targeting in the anterior thalamic area is superior to indirect targeting due to extensive individual variation in the location of ANT. Without detailed imaging information, however, a single trajectory MER has little localizing value.
Super-refractory status epilepticus is a condition characterized by recurrence of status epilepticus despite use of deep general anesthesia, and it has high morbidity and mortality rates. We report a case of a 17-year-old boy with a prolonged super-refractory status epilepticus that eventually resolved after commencing deep brain stimulation of the centromedian nucleus of the thalamus. Later attempt to reduce stimulation parameters resulted in immediate relapse of status epilepticus, suggesting a pivotal role of deep brain stimulation in the treatment response. Deep brain stimulation may be a treatment option in super-refractory status epilepticus when other treatment options have failed. ANN NEUROL 2017;81:142-146.
Thousands of operations are annually guided with computer assisted surgery (CAS) technologies. As the use of these devices is rapidly increasing, the reliability of the devices becomes ever more critical. The problem of accuracy assessment of the devices has thus become relevant. During the past five years, over 200 hazardous situations have been documented in the MAUDE database during operations using these devices in the field of neurosurgery alone. Had the accuracy of these devices been periodically assessed pre-operatively, many of them might have been prevented.The technical accuracy of a commercial navigator enabling the use of both optical (OTS) and electromagnetic (EMTS) tracking systems was assessed in the hospital setting using accuracy assessment tools and methods developed by the authors of this paper. The technical accuracy was obtained by comparing the positions of the navigated tool tip with the phantom accuracy assessment points. Each assessment contained a total of 51 points and a region of surgical interest (ROSI) volume of 120x120x100 mm roughly mimicking the size of the human head.The error analysis provided a comprehensive understanding of the trend of accuracy of the surgical navigator modalities. This study showed that the technical accuracies of OTS and EMTS over the pre-determined ROSI were nearly equal. However, the placement of the particular modality hardware needs to be optimized for the surgical procedure. New applications of EMTS, which does not require rigid immobilization of the surgical area, are suggested.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.