Background: Inhalation therapy is the backbone of asthma and COPD control. However, inhaler adherence and device mishandling continue to be a problem in real life. Some studies have shown that using a patient-preferred inhaler may reduce device handling errors and improve adherence to prescribed chronic inhaler drug therapy. The aim of this study was to compare the preferences for commonly used inhaler devices in Germany in patients with chronic obstructive respiratory disease. We also pursued the question which properties of an inhaler device are particularly important to the user and what effects age, gender and type of disease (asthma or COPD) may have on device preference and handling errors. Methods: Prospective, open-label cross-sectional study in which 105 patients with asthma (58%) or COPD (42%) participated. Validated checklists were used to objectively assess inhaler technique and errors with 10 different placebo devices. For each device, patients were asked to test the handling, to assess the device properties and to name the device that they would most or least prefer. Results: Across the 10 placebo inhaler devices tested, patients needed an average of 1.22 attempts to error-free use. The device with the lowest mean number of attempts was the Turbohaler® (1.02), followed by the Nexthaler® (1.04), the Diskus® (1.07) and the Spiromax® (1.10). Patients over 60 years vs. younger age (p = 0.002) and COPD vs. asthma patients (p = 0.016) required more attempts to ensure correct use. 41% of the study participants chose one of the devices they already used as the most preferred inhaler. Overall, 20% opted for the Spiromax®, 15% for the Nexthaler® and 14% for the Turbohaler® or a pMDI. The least preferred device was the Elpenhaler® (0%). From a selection of 7 predefined inhaler attributes, patients stated easy handling as the most important for them. This was followed by short inhalation time and low inhalation resistance. Conclusions: Patient preference may vary between inhaler devices. The lowest number of attempts to error-free use was reported for the Turbohaler® and the Nexthaler®. The Spiromax® and the Nexthaler® achieved the best overall ratings and were the devices most preferred by patients.
Background: Inhalation therapy is the backbone of asthma and COPD control. However, inhaler adherence and device mishandling continue to be a problem in real life. Some studies have shown that using a patient-preferred inhaler may reduce device handling errors and improve adherence to prescribed chronic inhaler drug therapy. The aim of this study was to compare the preferences for commonly used inhaler devices in Germany in patients with chronic obstructive respiratory disease. We also pursued the question which properties of an inhaler device are particularly important to the user and what effects age, gender and type of disease (asthma or COPD) may have on device preference and handling errors.Methods: Prospective, open-label cross-sectional study in which 105 patients with asthma (58%) or COPD (42%) participated. Validated checklists were used to objectively assess inhaler technique and errors with 10 different placebo devices. For each device, patients were asked to test the handling, to assess the device properties and to name the device that they would most or least prefer.Results: Across the 10 placebo inhaler devices tested, patients needed an average of 1.22 attempts to error-free use. The device with the lowest mean number of attempts was the Turbohaler® (1.02), followed by the Nexthaler® (1.04), the Diskus® (1.07) and the Spiromax® (1.10). Patients over 60 years vs. younger age (p=0.002) and COPD vs. asthma patients (p=0.016) required more attempts to ensure correct use. 41% of the study participants chose one of the devices they already used as the most preferred inhaler. Overall, 20% opted for the Spiromax®, 15% for the Nexthaler® and 14% for the Turbohaler® or a pMDI. The least preferred device was the Elpenhaler® (0%). From a selection of 7 predefined inhaler attributes, patients stated easy handling as the most important for them. This was followed by short inhalation time and low inhalation resistance.Conclusions: Patient preference may vary between inhaler devices. The lowest number of attempts to error-free use was reported for the Turbohaler® and the Nexthaler®. The Spiromax® and the Nexthaler® achieved the best overall ratings and were the devices most preferred by patients.
Purpose Transport of secretory immunoglobulin A (SIgA) through the airway epithelial cell barrier into the mucosal lumen by the polymeric immunoglobulin receptor (pIgR) is an important mechanism of respiratory mucosal host defense. Identification of immunomodulating substances that regulate secretory immunity might have therapeutic implications with regard to an improved immune exclusion. Thus, we sought to analyze secretory immunity under homeostatic and immunomodulating conditions in different compartments of the murine upper and lower respiratory tract (URT&LRT). Methods Pigr gene expression in lung, trachea, and nasal-associated lymphoid tissue (NALT) of germ-free mice, specific pathogen-free mice, mice with an undefined microbiome, as well as LPS- and IFN-γ-treated mice was determined by quantitative real-time PCR. IgA levels in bronchoalveolar lavage (BAL), nasal lavage (NAL), and serum were determined by ELISA. LPS- and IFN-γ-treated mice were colonized with Streptococcus pneumoniae and bacterial CFUs were determined in URT and LRT. Results Respiratory Pigr expression and IgA levels were dependent on the degree of exposure to environmental microbial stimuli. While immunostimulation with LPS and IFN-γ differentially impacts respiratory Pigr expression and IgA in URT vs. LRT, only prophylactic IFN-γ treatment reduces nasal colonization with S. pneumoniae. Conclusion Airway-associated secretory immunity can be partly modulated by exposure to microbial ligands and proinflammatory stimuli. Prophylactic IFN-γ-treatment modestly improves antibacterial immunity in the URT, but this does not appear to be mediated by SIgA or pIgR.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.