Primer extension reaction (PEXT) is the most widely used approach to genotyping of single nucleotide polymorphisms (SNP). It is based on the high accuracy of nucleotide incorporation by the DNA polymerase. We propose a dual-analyte bio/chemiluminometric method for the simultaneous detection of the PEXT reaction products of the normal and mutant allele in a high sample-throughput format. PCR-amplified DNA fragments that span the SNP of interest are subjected to two PEXT reactions using normal and mutant primers in the presence of digoxigenin-dUTP and biotin-dUTP. Both primers contain a d(A)30 segment at the 5'-end but differ in the final nucleotide at the 3'-end. Under optimized conditions only the primer that is perfectly complementary with the interrogated DNA will be extended by DNA polymerase and lead to a digoxigenin- or biotin-labeled product. The products of the PEXT reactions are mixed, denatured, and captured in microtiter wells through hybridization with immobilized oligo(dT) strands. Detection is performed by adding a mixture of antidigoxigenin-alkaline phosphatase (ALP) conjugate and a streptavidin-aequorin conjugate. The flash-type bioluminescent reaction of aequorin is triggered by the addition of Ca2+. ALP is then measured by adding the appropriate chemiluminogenic substrate. The method was evaluated by genotyping two SNPs of the human mannose-binding lectin gene (MBL2) and one SNP of the cytochrome P450 gene CYP2D6. Patient genotypes showed 100% concordance with direct DNA sequencing data.
We have developed a dry-reagent dipstick test for simultaneous visual detection of two alleles in single nucleotide polymorphisms (SNPs). The strip comprises two test zones and a control zone. Oligonucleotidefunctionalized gold nanoparticles are used as reporters. PCR-amplified DNA that spans the interrogated sequence is subjected to primer extension (PEXT) reactions using allele-specific primers. Digoxigenin-dUTP and biotin-dUTP are incorporated in the extended fragments. The primers contain an oligo(dA) segment at the 5 0 end. The PEXT products are applied to the sample area of the strip, which is then immersed in the appropriate buffer. As the buffer migrates along the strip by capillary action, the extension products of the two alleles are captured at the test zones from immobilized anti-digoxigenin and streptavidin, whereas the oligo(dA) segment of the primers hybridizes with oligo(dT) strands attached to gold nanoparticles, thus generating characteristic red lines. The excess nanoparticles are captured from immobilized oligo(dA) strands at the control zone of the strip. The test was applied to the genotyping of two SNPs of the Toll-like receptor 4 gene (Asp299Gly and Thr399Ile), one SNP of CYP2C19 gene (CYP2C19*3) and one SNP of the TPMT gene (TPMT*2). Contrary to most genotyping methods, the dipstick test does not require costly specialized equipment for detection of PEXT products. The PCR product is pipetted directly into the PEXT reaction mixture without prior purification. The high sensitivity of the strip allows completion of PEXT reaction in three cycles only (7 min). The visual detection of both alleles is complete in 15 min.
During the last 5 years, it was discovered that the JAK2V617F somatic mutation is present in virtually all patients with polycythemia vera and a large proportion of patients with essential thrombocythemia, primary myelofibrosis, and refractory anemia with ring sideroblasts and thrombocytosis. As a result, JAK2V617F was incorporated as a new clonal marker in the 2008 revision of the WHO diagnostic criteria. Current methods for JAK2 genotyping include direct sequencing, pyrosequencing, allele-specific PCR with electrophoresis, restriction fragment length polymorphism, real-time PCR, DNA-melting curve analysis, and denaturing HPLC. Some of these methods are labor intensive and time consuming, while the others require specialized costly equipment and reagents. We report a method for direct detection of the JAK2V617F allele by the naked eye using a dipstick test in a dry-reagent format. The method comprises a triprimer PCR combined with visual detection of the products within minutes by the dipstick test. Specialized instrumentation is not involved. The requirements for highly qualified technical personnel are minimized. Because the detection reagents exist in dry form on the dipstick, there is no need for multiple pipetting and incubation steps.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.