A simple, inexpensive, and environmentally friendly method based on ultrasound-assisted emulsification microextraction followed by solidification of floating organic drop and high-performance liquid chromatography coupled to diode array detection was developed for the simultaneous determination of 18 potentially allergenic fragrance substances. Several parameters affecting the microextraction process were investigated in detail by the "one-variable-at-a-time" approach. Optimal conditions were the following: 50 μL of 2-dodecanol as extraction solvent, 10 mL of sample containing 150 g/L of salt, and 5 min of sonication at 35°C. Under the optimized conditions, method showed good linearity in the selected ranges, with squared correlation coefficients ranging from 0.948 to 0.999. Limits of detection ranged from 0.001 to 0.154 μg/mL and enrichment factors from 9 to 237. Precision of the method, expressed as relative standard deviation, was checked at two levels obtaining good results (3.3-14.4%). Recovery studies were made in baby bath water and in eau de cologne showing acceptable accuracy. Finally, the developed method was successfully applied to different commercial cosmetic and water samples. The most commonly found analyte was linalool followed by cinnamal and lilial. Most of the analyzed samples contained at least one of the target compounds.
A simple and inexpensive method for cadmium determination in water using dispersive liquid-liquid microextraction and ultraviolet-visible spectrophotometry was developed. In order to obtain the best experimental conditions, experimental design was applied. Calibration was made in the range of 10–100 μg/L, obtaining good linearity (R2 = 0.9947). The obtained limit of detection based on calibration curve was 8.5 μg/L. Intra- and interday repeatability were checked at two levels, obtaining relative standard deviation values from 9.0 to 13.3%. The enrichment factor had a value of 73. Metal interferences were also checked and tolerable limits were evaluated. Finally, the method was applied to cadmium determination in real spiked water samples. Therefore, the method showed potential applicability for cadmium determination in highly contaminated liquid samples.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.