Purpose This study evaluates the Argus™ II Retinal Prosthesis System in blind subjects with severe outer retinal degeneration. Design The study design is a single arm, prospective, multicenter clinical trial. Participants Thirty subjects were enrolled in the United States and Europe between 6 June 2007 and 11 August 2009. All subjects were followed for a minimum of six months and up to 2.7 years. Methods The electronic stimulator and antenna of the implant was sutured onto the sclera using an encircling silicone band. Next, a pars plana vitrectomy was performed and the electrode array and cable were introduced into the eye via a pars plana sclerotomy. The microelectrode array was then tacked to the epiretinal surface. Main Outcome Measures The primary safety endpoint for the trial was the number, severity, and relation of adverse events. Principal performance endpoints were assessments of visual function as well as performance on orientation and mobility tasks. Results Subjects performed statistically better with system ON vs. OFF in the following tasks: object localization (96% of subjects); motion discrimination (57%); and discrimination of oriented gratings (23%). The best recorded visual acuity to date is 20/1260. Subjects’ mean performance on Orientation and Mobility tasks was significantly better when the System was ON vs. OFF. Seventy percent of the patients did not have any serious adverse events (SAEs). The most common SAE reported was either conjunctival erosion or dehiscence over the extraocular implant and was successfully treated in all subjects except in one which required explantation of the device without further complications. Conclusions The long-term safety results of Second Sight’s retinal prosthesis system are acceptable and the majority of subjects with profound visual loss perform better on visual tasks with system than without.
Purpose The Argus® II Retinal Prosthesis System (Second Sight Medical Products, Inc., Sylmar, CA) was developed to restore some vision to patients blind from retinitis pigmentosa (RP) or outer retinal degeneration. A clinical trial was initiated in 2006 to study the long-term safety and efficacy of the Argus II System in patients with bare or no light perception due to end-stage RP. Design The study is a prospective, multicenter, single-arm, clinical trial. Within-patient controls included the non-implanted fellow eye and patients' native residual vision compared to their vision when using the System. Subjects There were 30 subjects in 10 centers in the U.S. and Europe. Methods The worse-seeing eye of blind patients was implanted with the Argus II System. Patients wore glasses mounted with a small camera and a video processor that converted images into stimulation patterns sent to the electrode array on the retina. Main Outcome Measures The primary outcome measures were safety (the number, seriousness, and relatedness of adverse events) and visual function, as measured by three computer-based, objective tests. Secondary measures included functional vision performance on objectively-scored real-world tasks. Results Twenty-four out of 30 patients remained implanted with functioning Argus II Systems at 5 years post-implant. Only one additional serious adverse event was experienced since the 3-year time point. Patients performed significantly better with the System ON than OFF on all visual function tests and functional vision tasks. Conclusions The five-year results of the Argus II trial support the long-term safety profile and benefit of the Argus II System for patients blind from RP. The Argus II is the first and only retinal implant to have market approval in the European Economic Area, the United States, and Canada.
Purpose Retinitis Pigmentosa (RP) is a group of inherited retinal degenerations leading to blindness due to photoreceptor loss. A rare disease, it affects about 100,000 people in the United States. There is no cure and no approved medical therapy to slow or reverse RP. The purpose of this clinical trial was to evaluate the safety, reliability, and benefit of the Argus® II Retinal Prosthesis System (Second Sight Medical Products, Inc., Sylmar, CA) in restoring some visual function to subjects completely blind from RP. Herein, we report clinical trial results at 1 and 3 years post-implant. Design The study is a multicenter, single-arm, prospective clinical trial. Subjects There were 30 subjects in 10 centers in the U.S. and Europe. Subjects served as their own controls – i.e., implanted eye vs. fellow eye, and System ON vs. System OFF (native residual vision). Methods The Argus II System was implanted on and in a single eye (typically the worse-seeing eye) of blind subjects. Subjects wore glasses mounted with a small camera and a video processor that converted images into stimulation patterns sent to the electrode array on the retina. Main Outcome Measures The primary outcome measures were safety (the number, seriousness, and relatedness of adverse events) and visual function, as measured by three computer-based, objective tests. Results Twenty-nine out of 30 subjects remained implanted with functioning Argus II Systems at 3 years post-implant. Eleven subjects experienced a total of 23 serious device- or surgery-related adverse events. All were treated with standard ophthalmic care. As a group, subjects performed significantly better with the System ON than OFF on all visual function tests and functional vision assessments. Conclusions The three-year results of the Argus II trial support the long-term safety profile and benefit of the Argus II System for patients blind from RP. Earlier results from this trial were used to gain approval of the Argus II by the FDA and a CE Mark in Europe. The Argus II System is the first and only retinal implant to have both approvals.
BackgroundRetinal prosthesis systems (RPS) are a novel treatment for profound vision loss in outer retinal dystrophies. Ideal prostheses would offer stable, long-term retinal stimulation and reproducible spatial resolution in a portable form appropriate for daily life.MethodsWe report a prospective, internally controlled, multicentre trial of the Argus II system. Twenty-eight subjects with light perception vision received a retinal implant. Controlled, closed-group, forced-choice letter identification, and, open-choice two-, three- and four-letter word identification tests were carried out.ResultsThe mean±SD percentage correct letter identification for 21 subjects tested were: letters L, T, E, J, F, H, I, U, 72.3±24.6% system on and 17.7±12.9% system off; letters A, Z, Q, V, N, W, O, C, D, M, 55.0±27.4% system on and 11.8%±10.7% system off, and letters K, R, G, X, B, Y, S, P, 51.7±28.9% system on and 15.3±7.4% system off. (p<0.001 for all groups). A subgroup of six subjects was able to consistently read letters of reduced size, the smallest measuring 0.9 cm (1.7°) at 30 cm, and four subjects correctly identify unrehearsed two-, three- and four-letter words. Average implant duration was 19.9 months.ConclusionsMultiple blind subjects fitted with the Argus II system consistently identified letters and words using the device, indicating reproducible spatial resolution. This, in combination with stable, long-term function, represents significant progress in the evolution of artificial sight.
Background/aims To determine to what extent subjects implanted with the Argus II retinal prosthesis can improve performance compared with residual native vision in a spatial-motor task. Methods High-contrast square stimuli (5.85 cm sides) were displayed in random locations on a 19″ (48.3 cm) touch screen monitor located 12″ (30.5 cm) in front of the subject. Subjects were instructed to locate and touch the square centre with the system on and then off (40 trials each). The coordinates of the square centre and location touched were recorded. Results Ninety-six percent (26/27) of subjects showed a significant improvement in accuracy and 93% (25/27) show a significant improvement in repeatability with the system on compared with off (p<0.05, Student t test). A group of five subjects that had both accuracy and repeatability values <250 pixels (7.4 cm) with the system off (ie, using only their residual vision) was significantly more accurate and repeatable than the remainder of the cohort (p<0.01). Of this group, four subjects showed a significant improvement in both accuracy and repeatability with the system on. Conclusion In a study on the largest cohort of visual prosthesis recipients to date, we found that artificial vision augments information from existing vision in a spatial-motor task. Clinical trials registry no NCT00407602.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.