This paper presents a detailed study on the transient response and stability of the automatic gain control (AGC) with a proportion-integral (PI) controller for a MEMS vibratory gyroscope, which constructs a closed-loop control system to make the gyroscope achieve a constant amplitude vibration at its resonant frequency. The nonlinear mathematical model for the control system is established by applying the averaging and linearization method, which is evaluated through numerical simulations. The stability and convergence characteristics of the whole loop are investigated by using the phase plane method and Routh–Hurwitz criterion. The analysis provides a quantitative methodology for selecting the system parameters to approach stability and an optimal transient response. The negative impact induced by drift of the resonant frequency and Q-factor is also discussed. Simulation results predicted by the model are shown to be in close agreement with the experimental results carried out on a doubly decoupled bulk micromachined gyroscope. By optimizing the control parameters, the measured rising time is less than 100 ms without obvious overshoot. The setting time of the whole loop is less than 200 ms with the relative fluctuation of velocity amplitude within approximately 16 ppm for an hour. The resulting overall performance of the gyroscope is tested under atmospheric pressure. The resonant frequencies and the Q-factor of the drive mode and sense mode are 2.986 kHz, 213 and 3.199 kHz, 233, respectively. The gyroscope achieves a scale factor of 27.6 mV/deg/s with nonlinearity less than 120 ppm in the full-scale range of 800° s−1. The threshold of sensitivity is measured to be about 0.005° s−1 with noise equivalent angular rate evaluated to be 0.001°/s/Hz1/2.
Abstract-This paper describes a high-resolution silicon-onglass axis gyroscope operating at atmospheric pressure. The mechanical structure is designed in such a way that it exhibits low cross coupling between drive and sense mode of less than 0.5% simulated using finite-element method and 1.35% verified by experimental measurements. Due to a symmetrically designed structure, the specified bandwidth can be maintained despite of fabrication imperfections. The fabrication process flow is based on a combination of silicon on glass bonding and deep reactive ion etching which results in a large proof mass and capacitances. A closed loop self-oscillation drive interface is used to resonate the gyroscope in the drive mode, which reaches steady-state after 150 ms. Using area-varying capacitors, large quality factors of 217 and 97 for drive and sense mode, respectively, were achieved operating at atmospheric pressure. A low drive voltage, with a 1 V peak-peak
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.