Circulating extracellular vesicles (EVs) are considered as potential biomarkers for treatment and diagnosis of many diseases. Most of the existing methods for the EV analysis only have a single function and thus reveal limited information carried by EVs. Herein, a phosphatidylserine-targeting peptide-facilitated design that enables the versatile analysis of circulating EVs for varying requirement is proposed. In the design, DNA probes are inserted into the EV membrane through hydrophobic interactions, and accelerate the removal of protective shielding from DNA-gated metal-organic framework, thereby releasing a large number of methylene blue molecules to amplify the electrochemical signal. Electrochemical results demonstrate equally high sensitivities toward the quantification of EVs derived from different cell sources using an indiscriminative DNA probe. More importantly, the probe can be endowed with extended function for more accurate classification of cell-specific features through the identification of specific EV biomarkers, and demonstrates the potential use in the diagnosis of cardiovascular in a principle-of-proof study for clinical application. Therefore, the method provides a versatile design for the identification of EV features, and may address the needs of clinical diagnosis in the future.
Background The research of the sensitivity and specificity point-of-care testing (POCT) of D-dimer as a diagnostic protocol for differential diagnosis of Stanford Type A aortic syndrome (hereafter as TAAS) mimicking ST-elevated myocardial infarction (STEMI) with regular STEMI in the emergency department is limited. Methods Full medical information of 32 patients confirmed TAAS and 527 patients confirmed STEMI from January 1st, 2016 to October 1st, 2021 were retrospectively analyzed in Shanghai Tenth People’s Hospital of Tongji University. Results The baseline characteristics of two groups of patients were well-balanced post propensity score matching (PSM) analysis, and each group had 32 patients enrolled. Patients in the STEMI group had higher positive cardiac troponin I (cTNI) (0.174 ng/ml vs. 0.055 ng/ml, P = 0.008) results but lower D-dimer (0.365μg/ml vs. 31.50μg/ml, P < 0.001) results than the TAAS group. The D-dimer cutoff value of 2.155μg/ml had the best sensitivity of 100% and specificity of 96.9%, and the positive predictive value (PPV) as well as the negative predictive value (NPV) of the cutoff value were 96.9 and 100%, respectively, in total 64 patients, the area under the curve (AUC) values were 0.998 (95% CI:0.992-1.000, P < 0.001) for the D-dimer. No significant correlation between the D-dimer concentration and the time from symptoms onset to first medical contact in both groups (TAAS group: r = − 0.248, P = 0.170; STEMI group: r = − 0.159, P = 0.383) or significant correlation between D-dimer and creatine clearance (TAAS group: r = − 0.065, P = 0.765; STEMI group: r = 0.222, P = 0.221). The total in-hospital mortality for the patients with TAAS presenting as STEMI was 62.5% (20/32). The mortality rate for TAAS patients confirmed by computed tomography angiography (CTA) was significantly lower (40% vs. 82.4%, P = 0.014) than the mortality rate for TAAS patients confirmed by coronary angiography (CAG) and had a longer average survival time (log-rank = 0.015), less peri-surgical complications especially gastrointestinal hemorrhage (0.00% vs. 55.6%, P < 0.001). CTA diagnosis can reduce the mortality rate by 67.5% (95%CI:0.124-0.850, P = 0.16). Conclusions The POCT D-dimer with cut-off 2.155μg/ml would be useful to rule-out TAAS mimicking STEMI from regular STEMI prior to reperfusion therapy. CTA diagnosis is effective in reducing the probability of perioperative complications and lowering perioperative mortality than CAG diagnosis in TAAS patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.