AAA and Acuros XB were found to predict the dose under small MLC defined field segments well. While DLG and focal spot affect mostly the penumbra, the choice of correct MLC transmission will be essential to model treatments such as VMAT accurately.
BackgroundTo analyze interfraction motion of seminal vesicles (SV), and its motion relative to rectal and bladder filling.Methods and MaterialsSV and prostate were contoured on 771 daily computed tomography “on rails” scans from 24 prostate cancer patients undergoing radiotherapy. Random and systematic errors for SV centroid displacement were measured relative to the prostate centroid. Margins required for complete geometric coverage of SV were determined using isotropic expansion of reference contours. SV motion relative to rectum and bladder was determined.ResultsSystematic error for the SV was 1.9 mm left-right (LR), 2.9 mm anterior-posterior (AP) and 3.6 mm superior-inferior (SI). Random error was 1.4 mm (LR), 2.7 mm (AP) and 2.1 mm (SI). 10 mm margins covered the entire left SV and right SV on at least 90% of fractions in 50% and 33% of patients and 15 mm margins covered 88% and 79% respectively. SV AP movement correlated with movement of the most posterior point of the bladder (mean R2 = 0.46, SD = 0.24) and rectal area (mean R2 = 0.38, SD = 0.21).ConclusionsConsiderable interfraction displacement of SV was observed in this cohort of patients. Bladder and rectal parameters correlated with SV movement.
BackgroundTo compare 3 Dimensional Conformal radiotherapy (3D-CRT) with Intensity Modulated Radiotherapy (IMRT) with Volumetric-Modulated Arc Therapy (VMAT) for bladder cancer.MethodsRadiotherapy plans for 15 patients with T2-T4N0M0 bladder cancer were prospectively developed for 3-DCRT, IMRT and VMAT using Varian Eclipse planning system. The same radiation therapist carried out all planning and the same clinical dosimetric constraints were used. 10 of the patients with well localised tumours had a simultaneous infield boost (SIB) of the primary tumour planned for both IMRT and VMAT. Tumour control probabilities and normal tissue complication probabilities were calculated.ResultsMean planning time for 3D-CRT, IMRT and VMAT was 30.0, 49.3, and 141.0 minutes respectively. The mean PTV conformity (CI) index for 3D-CRT was 1.32, for IMRT 1.05, and for VMAT 1.05. The PTV Homogeneity (HI) index was 0.080 for 3D-CRT, 0.073 for IMRT and 0.086 for VMAT. Tumour control and normal tissue complication probabilities were similar for 3D-CRT, IMRT and VMAT. The mean monitor units were 267 (range 250–293) for 3D-CRT; 824 (range 641–1083) for IMRT; and 403 (range 333–489) for VMAT (P < 0.05). Average treatment delivery time were 2:25min (range 2:01–3:09) for 3D-CRT; 4:39 (range 3:41–6:40) for IMRT; and 1:14 (range 1:13–1:14) for VMAT. In selected patients, the SIB did not result in a higher dose to small bowel or rectum.ConclusionsVMAT is associated with similar dosimetric advantages as IMRT over 3D-CRT for muscle invasive bladder cancer. VMAT is associated with faster delivery times and less number of mean monitor units than IMRT. SIB is feasible in selected patients with localized tumours.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.