Studies of the indoor airborne microbiome have mostly been confined to a single location and time point. Here, we characterized, over the course of a year, the geographic variation, building-function dependence, and dispersal characteristics of indoor and outdoor airborne microbiomes (bacterial members only) of eight mechanically ventilated commercial buildings. Based on the Sloan neutral model, airborne microbiomes were randomly dispersed in the respective indoor and outdoor environments and between the two environments during each season. The dominant taxa in the indoor and outdoor environments showed minor variations at each location among seasons. The airborne microbiomes displayed weak seasonality for both indoor and outdoor environments, while a weak geographic variation was found only for the indoor environments. Source tracking results show that outdoor air and occupant skin were major contributors to the indoor airborne microbiomes, but the extent of the contribution from each source varied within and among buildings over the seasons, which suggests variations in local building use. Based on 32 cases of indoor airborne microbiome data, we determined that the indoor/outdoor (I/O) ratio of PM 2.5 was not a robust indicator of the sources found indoors. Alternatively, the indoor concentration of carbon dioxide was more closely correlated with the major sources of the indoor airborne microbiome in mechanically ventilated environments.
When a stent is implanted in a blocked ureter, the urine passing from the kidney to the bladder must traverse a very complicated flow path. That path consists of two parallel passages, one of which is the bore of the stent and the other is the annular space between the external surface of the stent and the inner wall of the ureter. The flow path is further complicated by the presence of numerous pass-through holes that are deployed along the length of the stent. These holes allow urine to pass between the annulus and the bore. Further complexity in the pattern of the urine flow occurs because the coiled "pig tails," which hold the stent in place, contain multiple ports for fluid ingress and egress. The fluid flow in a stented ureter has been quantitatively analyzed here for the first time using numerical simulation. The numerical solutions obtained here fully reveal the details of the urine flow throughout the entire stented ureter. It was found that in the absence of blockages, most of the pass-through holes are inactive. Furthermore, only the port in each coiled pig tail that is nearest the stent proper is actively involved in the urine flow. Only in the presence of blockages, which may occur due to encrustation or biofouling, are the numerous pass-through holes activated. The numerical simulations are able to track the urine flow through the pass-through holes as well as adjacent to the blockages. The simulations are also able to provide highly accurate results for the kidney-to-bladder urine flow rate. The simulation method presented here constitutes a powerful new tool for rational design of ureteral stents in the future.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.