Moderate to severe ipsilateral shoulder pain is a common complaint following thoracic surgery. In this prospective, parallel-group study at Odense University Hospital, 76 patients (aged > 18 years) scheduled for lobectomy or pneumonectomy were randomised 1:1 using a computer-generated list to receive an ultrasound-guided supraclavicular phrenic nerve block with 10 ml ropivacaine or 10 ml saline (placebo) immediately following surgery. A nerve catheter was subsequently inserted and treatment continued for 3 days. The study drug was pharmaceutically pre-packed in sequentially numbered identical vials assuring that all participants, healthcare providers and data collectors were blinded. The primary outcome was the incidence of unilateral shoulder pain within the first 6 h after surgery. Pain was evaluated using a numeric rating scale. Nine of 38 patients in the ropivacaine group and 26 of 38 patients in the placebo group experienced shoulder pain during the first 6 h after surgery (absolute risk reduction 44% (95% CI 22-67%), relative risk reduction 65% (95% CI 41-80%); p = 0.00009). No major complications, including respiratory compromise or nerve injury, were observed. We conclude that ultrasound-guided supraclavicular phrenic nerve block is an effective technique for reducing the incidence of ipsilateral shoulder pain after thoracic surgery.
Background One-lung ventilation (OLV) procedures are essential for most thoracic surgeries, and the most common method is intubation with a conventional double-lumen tube (cDLT) and bronchoscopy to verify correct tube placement. Objective The objective of this study was to conduct a cost-effectiveness analysis comparing the VivaSight double-lumen tube (DL) and a cDLT for OLV procedures. Methods A cost-effectiveness analysis was conducted from a healthcare sector perspective in Denmark using a decision analytic model to assess the potential effects and costs of using VivaSight-DL as an alternative to a cDLT with a reusable bronchoscope. Costs were determined using a micro-costing approach. The effectiveness measure was the number of times that fiberoptic confirmation of the tube placement during intubation or surgery was unnecessary and thus avoided. The effectiveness input was from a randomized controlled trial (n = 52). Both deterministic and probabilistic sensitivity analyses were conducted to assess the robustness of the results. Results Fiberoptic confirmation of tube placement was only necessary in two (6.66%) procedures using VivaSight-DL. The cost of using VivaSight-DL was $US299.96 per procedure versus $US347.61 for a cDLT with a reusable bronchoscope. The incremental cost-effectiveness ratio was − $US51.06 per bronchoscopy avoided. The base-case analysis indicated that the use of VivaSight-DL was cost effective compared with the use of a cDLT with reusable bronchoscope. Sensitivity analyses showed that the results were robust and that VivaSight-DL was more effective and less costly. Conclusion This study suggests that VivaSight-DL is associated with cost savings and reductions in bronchoscope use to verify correct tube placement. The conclusion is based on the results from a single institution. To clarify whether VivaSight-DL is cost effective in larger or global clinical settings, further economic evaluations should be performed.
In patients with acute kidney injury (AKI) mortality remains high, despite the fact that the patients are treated with continuous renal replacement therapy. The interaction between the kidney and the immune system might explain the high mortality observed in AKI. In order to elucidate the interaction between the kidney and immune system we developed a two-hit model of AKI and endotoxemia. Our hypothesis was that ischemia/reperfusion (I/R) of the kidney simultaneously with endotoxemia would generate a more extensive inflammatory response compared to I/R of the hind legs. Our expectation was that elevated levels of cytokines would be found in both blood and in organs distant to the kidneys. Forty mice were divided into five groups. The mice were subjected to the following operations: A: Sham only, no lipopolysaccharide (LPS); B: I/R of both kidneys + LPS; C: LPS only; D: Nephrectomy + LPS; E: I/R of both hind legs + LPS. In groups B and E, I/R times were identical. All mice were kept alive for 24 h and then sacrificed. Levels of interleukin (IL)-1β, IL-6, IL-10, and tumor necrosis factor-α were measured in the blood. The activity of myeloperoxidase (MPO) in lungs, kidneys, and liver was evaluated as an indirect measurement of accumulation of granulocytes. In this study, significantly higher amount of IL-6 and IL-10 in the plasma was observed following renal I/R compared to hind leg I/R. The elevated levels of cytokine in plasma were observed following nephrectomy and endotoxemia. The neutrophil infiltration of distant organs measured by the levels of MPO in the lung and liver also showed a significantly higher level in renal I/R compared to hind leg I/R. Renal I/R is associated with a more pronounced inflammatory response in blood and distant organs. The high cytokine levels measured following nephrectomy might be explained by compromised elimination of cytokines by the kidney in AKI.
BackgroundPhysicians working in prehospital care are expected to handle radio communication both within their own sector as well as with other divisions of the National Emergency Services. To date, no study has been conducted on the level of training received by physicians in the use of the equipment provided or on the level of competency acquired by physicians.MethodsIn order to investigate the self-assessed skill level acquired in the use of the TETRA (TErrestrial Trunked RAdio) authority radio for communication in a prehospital setting, a cross-sectional study was conducted by questionnaire circulated to all 454 physicians working in the Danish Emergency Medical Services.ResultsA lack of training was found among physicians working in prehospital care in Denmark in relation to the proper use of essential communication equipment. Prior to starting their first shift in a prehospital setting 38% of physicians reported having received no training in the use of the equipment, while 80% of physicians reported having received one1 hour of training or less. Among the majority of physicians their current level of training was sufficient for their everyday needs for prehospital communication but for 28% of physicians their current level of training was insufficient as they were unable to handle communication at this level.ConclusionAs the first study in its field, this study investigated the training received in the use of essential communication equipment among physicians working in prehospital care in Denmark. The study found that competency does not appear to have been prioritised as highly as other technical skills needed to function in these settings. For the majority of physicians their current level of training was sufficient for everyday use but for a substantial minority further training is required, especially if the redundancy of the prehospital system is to be preserved.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.