Orthokeratology has been widely used to control myopia, but the mechanism is still unknown. To further investigate the underlying mechanism of corneal reshaping using orthokeratology lenses via the finite element method, numerical models with different corneal curvatures, corneal thicknesses, and myopia reduction degrees had been developed and validated to simulate the corneal response and quantify the changes in maximum stress in the central and peripheral corneal areas during orthokeratology. The influence of the factors on corneal response had been analyzed by using median quantile regression. A partial eta squared value in analysis of variance models was established to compare the effect size of these factors. The results showed central and peripheral corneal stress responses changed significantly with increased myopia reduction, corneal curvature, and corneal thickness. The target myopia reduction had the greatest effect on the central corneal stress value (partial eta square = 0.9382), followed by corneal curvature (partial eta square = 0.5650) and corneal thickness (partial eta square = 0.1975). The corneal curvature had the greatest effect on the peripheral corneal stress value (partial eta square = 0.5220), followed by myopia reduction (partial eta square = 0.2375) and corneal thickness (partial eta square = 0.1972). In summary, the biomechanical response of the cornea varies significantly with the change in corneal conditions and lens designs. Therefore, the orthokeratology lens design and the lens fitting process should be taken into consideration in clinical practice, especially for patients with high myopia and steep corneas.
Acanthamoeba keratitis (AK) is a rare but severe ocular infection with a significant risk of vision loss. Contact lens use is the main risk factor for AK. The orthokeratology (OK) lens, a specially designed contact lens, has been used worldwide as an effective method of myopia control. However, the OK lens is associated with an increased risk of Acanthamoeba infection. Many primary practitioners are concerned about this infection because of its relative rarity, the lack of promising therapeutic medications, and the need for referral. We herein report two cases of AK associated with OK lenses, present a systematic review of such cases, and discuss the possible reasons for the higher incidence rate of this infection in patients who wear OK lenses. We combined the clinical knowledge and skills of corneal specialists and lens experts with the sole objective of addressing these OK lens-related AK cases. We found that the most common risk factors were rinsing the lenses or lens cases with tap water. Prompt and accurate diagnosis along with adequate amoebicidal treatment are essential to ensure desirable outcomes for OK lens wearers who develop AK. Appropriate OK lens parameters and regular checkups are also important.
Introduction: This study developed and validated a nomogram for predicting the risk of second surgery in patients with concomitant esotropia (CE) based on a cohort in Beijing. Methods: In this retrospective cohort study, the inpatient and outpatient medical records of 419 patients with CE who underwent surgery at the Peking University First Hospital between January 1, 2005 and December 31, 2009 were collected. A total of 357 CE cases were included. For those cases 70% were randomly assigned to the training set (n = 234) and 30% to the validation set (n = 123). Demographic and clinical variables were ascertained at hospital admission and discharge and screened using multivariate Cox proportional hazards regression analysis to construct predictive models and generate a 1-, 4-, and 8-year overall survival nomogram. This nomogram provided an estimate of the risk of second surgery in patients with surgically treated CE. Internal validation was conducted using the concordance index (C-index) and calibration curve for the training and validation sets. Results: Six independent prognostic factors were identified, namely age at surgery, age at onset, amblyopia, deviation angles, surgical amount, and deviation angles 1 week after surgery, and these were entered into the nomogram. The proposed nomogram showed favorable discrimination and accuracy in the training and validation sets. The C-indexes of the training and validation sets were 0.84 (95% CI 0.79-0.89) and 0.80 (95% CI 0.78-0.82), respectively. Conclusions: The proposed nomogram can serve as a predictive tool for prognostic evaluation of CE surgery.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.