An ultrasensitive method based on Surface enhanced Raman scattering (SERS) has been developed to determine content of a pesticide which is tricyclazole in paddy rice using sliver colloid as a substrate and pyridine as an internal standard. The peaks at 424 and 1035 cm(-1) in a SERS spectrum were selected as analytic and internal peaks, respectively, and their intensity ratio I(t)/I(p) was used to calculate the regression concentration of tricyclazole. The correlation between I(t)/I(p) and concentration showed significant linear relationship with a correlation coefficient of R(2)= 0.995 in a concentration range of 0.05 to 0.70 mg/L and the tricyclazole solution can be detected to be low as 0.002 mg/L by SERS. The method was applied to determine tricyclazole contents of 3 real rice samples with a standard addition method in order to eliminate interference of matrix. The errors of SERS measurements for the 3 samples were 0.0008 to 0.0246, 0.0013 to 0.0028, and 0.0129 to 0.0304 mg/kg, respectively, compared with the results obtained by high performance liquid chromatography method. This also showed a good reproducibility with low values of relative standard deviation (n= 3) for the 3 samples ranged from 3.63% to 4.64%.
We report on a simple, sensitive and selective method for the spectrophotometric determination of Ni 2+ in water samples. The analyte ions were collected on a membrane filter in the form of their red complex with 1-(2-pyridylazo)-2-naphthol (PAN), and the absorption spectra of the colored membrane filters were acquired. Effects of pH value, sample volume, and amount of PAN were examined in order to optimize sensitivity. The interference by common other ions was eliminated using appropriate masking agents. The absorbance is linearly related to the concentration of Ni 2+ in the ranges from 0.3 to 1.5 μg L −1 , and from 2 to 10 μg L −1 , respectively, the correlation coefficients (R 2 ) being 0.9871 and 0.9954. Under the optimal conditions, the detection limit is 0.1 μg L −1 . The recoveries in case of spiked samples are between 95.0% and 101.5%, and the relative standard deviations range from 2.8% to 4.1%.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.