This paper presents the results of the 4th International Comparison of in vitro electron paramagnetic resonance dosimetry with tooth enamel, where the performance parameters of tooth enamel dosimetry methods were compared among sixteen laboratories from all over the world. The participating laboratories were asked to determine a calibration curve with a set of tooth enamel powder samples provided by the organizers. Nine molar teeth extracted following medical indication from German donors and collected between 1997 and 2007 were prepared and irradiated at the Helmholtz Zentrum München. Five out of six samples were irradiated at 0.1, 0.2, 0.5, 1.0 and 1.5 Gy air kerma; and one unirradiated sample was kept as control. The doses delivered to the individual samples were unknown to the participants, who were asked to measure each sample nine times, and to report the EPR signal response, the mass of aliquots measured, and the parameters of EPR signal acquisition and signal evaluation. Critical dose and detection limit were calculated by the organizers on the basis of the calibration-curve parameters obtained at every laboratory. For calibration curves obtained by measuring every calibration sample three times, the mean value of the detection limit was 205 mGy, ranging from 56 to 649 mGy. The participants were also invited to provide the signal response and the nominal dose of their current dose calibration curve (wherever available), the critical dose and detection limit of which were also calculated by the organizers..
PurposePurpose: To present our experience with pulsed dose rate brachytherapy (PDR BT) of lip cancer.Material and methodsThe study group included 32 T1-4N0M0 lip cancer patients with a median age of 71 years (ranged 41-87 years), treated with interstitial PDR BT to the planned total dose of 60-70 Gy; 1 Gy/pulse, pulses repeated every hour a day. There were 26 untreated patients, and six patients after previous surgery including five implanted at the time of cancer relapse.ResultsPDR BT was delivered over few days and was well tolerated. After therapy, all patients experienced temporary, usually mild, acute mucositis. Late severe (Grade 3) mucositis of oral vestibule mucosa occurred in one case. Among 31 patients who completed the therapy, local control was achieved in 29 (93.5%). One patient with reccurrent upper lip T2 tumor was susccessfully salvaged surgically, another one died due to persisted T3 lip tumor with lymph node metastases. Overall, four patients developed neck nodal cancer relapse and two – distant metastases. The 5-year local control, and all-cause overall survival probabilities are 94% and 73%, respectively. Good/excellent cosmetic and functional outcome was obtained in all but two patients.ConclusionsPDR at the dose of 1 Gy/pulse is effective and well tolerated BT technique in treating lip cancer patients.
In the present study, bone samples from three patients treated in radiotherapy facilities in Poland were used for the determination of doses absorbed during radiotherapy. The samples were obtained during surgical treatments of patients performed due to medical indications. For the purpose of retrospective dosimetry, sensitivity of the radiation-induced EPR signal was individually calibrated in the samples by re-irradiation of the samples with known doses. The doses reconstructed in bones extracted within 6 months after irradiation were consistent with those calculated by treatment planning systems. The dose reconstructed in the bone removed 6 y after radiotherapy was ∼14% lower than the calculated one.
PurposeTo assess dose received by the left anterior descending (LAD) coronary artery during interstitial pulsed-dose-rate brachytherapy (PDR-BT) boost for left-sided breast cancer patients undergoing organ-sparing treatment.Material and methodsThirty consecutive pT1-3N0-1M0 breast cancer patients boosted between 2014 and 2015 with 10 Gy/10 pulses/hour PDR-BT following a computed tomography (CT) simulation with the multi-catheter implant were included. The most common localization of primary tumor were upper quadrants. Patients were implanted with rigid tubes following breast conserving surgery and whole breast external beam irradiation (40 Gy/15 or 50 Gy/25 fractions). Computed tomography scans were retrospectively reviewed and LADs were contoured without and with margin of 5 mm (LAD5mm). Standard treatment plan encompassed tumor bed determined by the surgical clips with margin of 2 cm. Dosimetric parameters were extracted from the dose-volume histograms.ResultsThe mean D90 and V100 were 10.3 Gy (range: 6.6-13.3), and 42.0 cc (range: 15.3-109.3), respectively. The median dose non-uniformity ratio (DNR) was 0.50 (range: 0.27-0.82). The mean doses to LAD and LAD5mm were 1.0 Gy and 0.96 Gy, and maximal doses were 1.57 Gy and 1.99 Gy, respectively. Dose to the 0.1 cc of the LAD and LAD5mm were 1.42 Gy and 1.85 Gy (range: 0.01-4.98 Gy and 0.1-6.89 Gy), respectively.ConclusionsInterstitial multi-catheter PDR-BT used as a boost for left-sided breast cancer is generally associated with low dose to the LAD. However, higher dose in individual cases may require alternative approaches.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.