Background: Highly accurate testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) at the point of care (POC) is an unmet diagnostic need in emergency care and time-sensitive outpatient care settings. Reverse transcription-polymerase chain reaction (RT-PCR) technology is the gold-standard for SARS-CoV-2 diagnostics. Methods: We performed a multi-site United States (US) study comparing the clinical performance of the first US Food and Drug Administration (FDA) authorized POC RT-PCR test for detection of SARS-CoV-2 in 20 minutes, the cobas® Liat SARS-CoV-2 & Influenza A/B nucleic acid test, to the most widely used RT-PCR laboratory test, the cobas® 68/8800 SARS-CoV-2 test. Results: Clinical nasopharyngeal swab specimens from 444 patients with 357 evaluable specimens at five US clinical laboratories were enrolled from September 21, 2020 to October 23, 2020. The overall agreement between the Liat and 68/8800 systems for SARS-CoV-2 diagnostics was 98.6% (352/357). Using Liat, positive percent agreement for SARS-CoV-2 was 100% (162/162) and the negative percent agreement was 97.4% (190/195). Conclusion: The Liat is an RT-PCR POC test that provides highly accurate SARS-CoV-2 results in 20 minutes with equivalent performance to high-throughput laboratory molecular testing. Rapid RT-PCR testing at the POC can enable more timely infection control and individual care decisions for Coronavirus Disease 2019.
Background Clinical guidelines for the diagnosis of group A streptococcal (GAS) pharyngitis recommend the use of a rapid antigen detection test (RADT) and/or bacterial culture. This study evaluated the overall diagnosis and treatment of acute pharyngitis in the United States, including predictors of test type and antibiotic prescription. Methods A retrospective analysis of pharyngitis events from 2011 through 2015 was conducted using the MarketScan commercial/Medicare databases. A pharyngitis event was defined as occurring within 2 weeks from the index visit. Patient and provider characteristics were examined across 5 testing categories: RADT, RADT plus culture, other tests, nucleic acid amplification testing (NAAT), and no test. Multivariate models were used to identify significant predictors of NAAT use and antibiotic prescription. Results A total of 18.8 million acute pharyngitis events were identified in 11.6 million patients. Roughly two-thirds of events (68.2%) occurred once, and roughly a third of patients (29.1%) required additional follow-up, but hospitalization was rare (0.3%). Across all events, 43% were diagnosed by RADT, while 20% were diagnosed by RADT plus culture. The proportion of events diagnosed by NAAT increased 3.5-fold from 2011 to 2015 (0.06% vs 0.27%). Antibiotic use was frequent (49.3%), less often in combination with RADT plus culture (31.2%) or NAAT alone (34.5%) but significantly more often with RADT alone (53.4%) or no test (57.1%). Pediatricians were significantly less likely than other providers to prescribe antibiotics in their patients, regardless of patient age ( p < 0.0001). Conclusions Antibiotic use for sore throat remains common, with many clinicians not following current guidelines for diagnosis of GAS pharyngitis. Diagnosis of GAS pharyngitis using RADT plus culture or NAAT alone was associated with lower use of antibiotics. Diagnostic testing can help lower the incidence of inappropriate antibiotic use, and inclusion of NAAT in the clinical guidelines for GAS pharyngitis warrants consideration. Electronic supplementary material The online version of this article (10.1186/s12879-019-3835-4) contains supplementary material, which is available to authorized users.
BackgroundTo compare the sensitivity and specificity of the recommended 2-step rapid antigen detection test (RADT) with confirmatory culture vs the point-of-care (POC) polymerase chain reaction (PCR) Roche cobas® Liat® Strep A test for detection of group A Streptococcus (GAS) in pediatric patients with pharyngitis, and to investigate the impact of these tests on antibiotic use in a large pediatric clinic.MethodsThis prospective, open-label study was conducted at a single site during fall/winter 2016–2017. A total of 275 patients aged 3 to 18 years with symptoms of pharyngitis had a throat-swab specimen analyzed using RADT, POC PCR, and culture. The sensitivity, specificity, and percentage agreement (95% CI) between assays and a laboratory-based nucleic acid amplification test were calculated. DNA sequencing was used to adjudicate discrepancies. The RADT or POC PCR result was provided to clinicians on alternating weeks to compare the impact on antibiotic use.ResultsA total of 255 samples were evaluated; 110 (43.1%) were GAS positive. Sensitivities (95% CI) for POC PCR, RADT, and culture were 95.5% (89.7–98.5%), 85.5% (77.5–1.5%), and 71.8% (62.4–80.0%), respectively. Specificities (95% CI) for POC PCR, RADT, and culture were 99.3% (96.2–99.98%), 93.7% (88.5–97.1%), and 100% (97.5–100%), respectively. Compared with RADT, POC PCR resulted in significantly greater appropriate antibiotic use (97.1% vs 87.5%; P = .0065).ConclusionUnder real-world conditions, RADT results were less specific and culture results were less sensitive than found in established literature and led to increased rates of inappropriate antibiotic use. POC PCR had high sensitivity and specificity and rapid turnaround times, and led to more appropriate antibiotic use.Trial registrationID number ISRCTN84562679. Registered October 162,018, retrospectively registered.
Rapid diagnosis of influenza A and B is important for direct treatment decisions in patient care and for the reduction of in-hospital transmissions. The new real-time PCR based molecular point-of-care (POC) assay, the cobas Influenza A/B test on the cobas Liat System (cobas Liat Influenza A/B assay), generated a PCR result in less than 20 min, was evaluated for the detection of influenza A and B. One hundred twenty-one retrospectively collected respiratory specimens, previously analyzed with a routine influenza A/B test (Diagenode) were tested using the cobas Liat Influenza A/B assay. The cobas Liat Influenza A/B assay allows influenza A and B testing by RT-PCR within 20 min. This assay detected influenza A in 51 of 56 samples positive by the Diagenode test. The five discrepant results were retested with the Cepheid Influenza A/B test, confirming two positive cases. All 30 influenza B Diagenode positive samples were found positive by the cobas Liat Influenza A/B assay. Control samples (viral negative and non-influenza pathogens) were all negative by the cobas Liat Influenza A/B assay. The cobas Liat Influenza A/B assay showed a sensitivity for influenza A/B of 96% and 100%, respectively, and 100% specificity for both targets. The cobas Liat Influenza A/B assay is a useful tool for accurate, rapid, and sensitive detection of influenza A and B, offering timely and personalized patient management and infection control when implemented at the point-of-care.
The performance of a polymerase chain reaction-based point-of-care assay, the cobas Strep A Nucleic Acid Test for use on the cobas Liat System (cobas Liat Strep A assay), for the detection of group A Streptococcus bacteria was evaluated in primary care settings. Throat swab specimens from 427 patients were tested with the cobas Liat Strep A assay and a rapid antigen detection test (RADT) by existing medical staff at 5 primary care clinics, and results were compared with bacterial culture. The cobas Liat Strep A assay demonstrated equivalent sensitivity (97.7%) and specificity (93.3%) to reference culture with a 15-minute turnaround time. In comparison to RADTs, the cobas Liat Strep A assay showed improved sensitivity (97.7% Liat vs 84.5% RADT). The Clinical Laboratory Improvement Amendments-waived cobas Liat Strep A assay demonstrated the ease of use and improved turnaround time of RADTs along with the sensitivity of culture.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.