Background:
Belatacept (Nulojix; Bristol-Myers Squibb, New York, NY) is a biological immunosuppressive drug used for the prophylaxis of acute rejection after renal transplantation. Few studies have described belatacept pharmacokinetics, and the effect of therapeutic drug monitoring has not been investigated. We have developed a drug-capture assay (using drug target) to measure belatacept in serum and applied this assay in a pharmacokinetic study in renal transplant recipients.
Methods:
CD80 was used to trap belatacept onto streptavidin-coated wells. Captured drug was quantified using Eu3+-labeled protein A and time-resolved fluorescence. The assay was applied in a pilot pharmacokinetic study in renal transplanted patients receiving belatacept infusions. Belatacept serum concentrations were determined at several time points between belatacept infusions. A simple population pharmacokinetic model was developed to visualize measured and predicted belatacept serum concentrations.
Results:
The assay range was 0.9–30 mg/L with accuracy within 91%–99% and coefficients of variation ranging from 1.2% to 3.6%. Predilution extended the measurement range to 130 mg/L with an accuracy of 90% and coefficients of variation of 3.8%. Samples were stable during storage at 4°C for 15 days and during 2 freeze-thaw cycles. Belatacept concentrations were determined in a total of 203 serum samples collected during 26 infusion intervals from 5 renal transplant recipients. The population pharmacokinetic model visualized both measured and predicted concentrations.
Conclusions:
We have developed an automated, accurate, and precise assay for the determination of belatacept serum concentrations. The assay was successfully applied in a pharmacokinetic study in renal transplant recipients receiving belatacept infusions.
This is a PDF file of an article that has undergone enhancements after acceptance, such as the addition of a cover page and metadata, and formatting for readability, but it is not yet the definitive version of record. This version will undergo additional copyediting, typesetting and review before it is published in its final form, but we are providing this version to give early visibility of the article. Please note that, during the production process, errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.