Previous studies regarding static energy meter errors under non-sinusoidal load conditions have shown that these meters can produce erroneous readings. This paper describes an investigation done using loads consisting of a commercial lighting dimmer in combination with either a resistive heater or an array of various energy-saving lamps. Dimmer impedance and phase firing angle were gradually adjusted to change load conditions. Several meters showed dramatic variations in metering error under different load conditions. In the most extreme case, metering errors ranged from five times the energy consumed by the load to registering almost no energy. Though perhaps not typically found in households, the load combinations used in this study were able to highlight sensitivities of different static energy meters to changes in load conditions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.