Das Tragverhalten von speziellen Gitterträgern als Durchstanzbewehrung wurde in Bauteilversuchen an 18 cm bis 36 cm dicken teilvorgefertigten Stahlbetonplatten mit horizontaler Verbundfuge untersucht. Variiert wurde unter anderem auch die Anordnung der vorgefertigten Platten. Die ermittelten Durchstanzwiderstände und das beobachtete Tragverhalten bestätigen die Effektivität dieser Bewehrungselemente. Die Versuche führten zur Erteilung einer europäischen technischen Zulassung (ETA) auf der Bemessungsgrundlage von Eurocode 2.Punching shear reinforcement for semi precast slabs according to Eurocode 2The load bearing behaviour of special lattice girders functioning as punching shear reinforcement has been tested in full scale tests with 18 cm up to 36 cm thick semi precast slabs with horizontal composite joints. Varied was among other parameter also the arrangement of the precast plates. The determined punching shear resistance and the load bearing behaviour confirmed the effectiveness of this reinforcement. These tests had led to an European Technical Approval (ETA) based on Eurocode 2.
Aufgrund des hohen Vorfertigungsgrads gewinnen Elementplatten auch in Flachdecken zunehmend an Bedeutung. Wegen der hohen Querkraft‐ und Momentenbeanspruchung im Bereich des Decke‐Stütze‐Knotens ist dessen konstruktive Durchbildung von sicherheitsrelevanter Bedeutung. In der Praxis wird der Abstand der Elementplatten zur Stütze unterschiedlich ausgeführt. In Anlehnung an die in Zulassungen von verschiedenen Durchstanzbewehrungssystemen geforderte Mindestbreite der Fuge zwischen den Elementplatten von 4 cm wird auch der Abstand zwischen Elementplatte und Stützenanschnitt teilweise so groß gewählt. Eine solche Bauausführung hat den Vorteil, dass Abmessungs‐ und Lagetoleranzen ausgeglichen werden können. Nachteilig ist jedoch die zusätzlich erforderliche Abschalung der Fuge nach unten. Daher wird in der Praxis ein Heranführen der Elementplatte bis direkt an die Stütze bevorzugt.Anhand einer systematischen Versuchsserie mit speziellen Gitterträgern als Durchstanzbewehrung wurde zwischenzeitlich nachgewiesen, dass kleinere Abstände zwischen Elementplatte und Stütze die Durchstanztragfähigkeit nicht abmindern. Zur Bestätigung dieses Zusammenhangs auch für andere Durchstanzbewehrungssysteme wurden am Institut für Massivbau der RWTH Aachen zwei Durchstanzversuche mit Doppelkopfankern und speziellen Gitterträgern als Durchstanzbewehrung durchgeführt. Die Elementplatten wurden direkt bis an die Stützenkante geführt. Um Montageungenauigkeiten zu berücksichtigen, wurden die vorgefertigten Stützen zusätzlich zu hoch betoniert. Der Vergleich der Versuchsergebnisse mit denen jeweiliger Referenzversuche erlaubt Empfehlungen zur konstruktiven Durchbildung des Decke‐Stütze‐Knotens bei der Verwendung von Elementplatten in Flachdecken.Construction of slab‐column‐connections in semi‐precast flat slabsDue to the high degree of prefabrication, semi‐precast flat slabs are gaining importance. In this context, the construction of the slab‐column‐connection has a safety‐related significance. In daily engineering practice, the joint widths between semi‐precast slabs as well as the joint widths between semi‐precast slabs and the column's vicinity is constructed differently. The European Technical Approvals of different punching shear reinforcement systems limit the minimum joint width between semi‐precast elements to 4 cm. Following these provisions, the joint widths between semi‐precast slabs and the column's vicinity is constructed with 4 cm in some cases. An advantage of this approach is the possibility to adjust dimensional and positional tolerances at construction site. However, a disadvantage is the additional formwork for the joint from the soffit.A systematic test series with special lattice girders as punching shear reinforcement showed no reduction of the punching shear resistance for smaller joint widths between semi‐precast slabs and the column's vicinity. To confirm these test results, two punching shear tests with double headed studs and lattice girders as punching shear reinforcement were conducted at Institute of Structural Concrete (RWTH Aachen). In the tests, the influence of the joint width between semi‐precast slabs and the column's vicinity as well as the influence of column height tolerances were investigated. Based on the results of the tests, this article gives recommendations for the construction of slab‐column‐connections in semi‐precast flat slabs.
Flachdecken werden wirtschaftlich aus vorgefertigten Stahlbetonplatten und einer aufbetonierten Ortbetonschicht hergestellt. Das Tragverhalten dieser Elementdecken mit Gitterträgern ist ähnlich dem von Ortbetondecken. Bei der Bemessung und Konstruktion von Elementdecken sind jedoch einige Besonderheiten zu beachten. Der Eurocode 2 mit zugehörigem nationalem Anhang [1] enthält Regelungen hierzu. Als Durchstanz‐ und Verbundbewehrung kommen jedoch Bewehrungssysteme zur Anwendung, welche auf der Grundlage von nationalen oder europäischen Zulassungen bemessen werden. Die erforderlichen Nachweise im Durchstanzbereich von Flachdecken werden für unterschiedliche Systeme zusammengestellt und erläutert.Flat Slabs built as Semi‐Precast Slabs with Lattice Girders. Advice to application according to Eurocode 2Flat slabs are economically made of precast slabs with insitu topping. The load bearing behaviour of these semi‐precast slabs with lattice girders is similar to in situ concrete slabs. Eurocode 2 together with the German annex [1] gives advice for that. The used punching shear reinforcement and composite reinforcement have to be designed according to national or European technical approvals. The necessary proofs in case of flat slabs are consolidated and explained.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.