Of patients with newly diagnosed multiple myeloma, approximately 10% have dialysis-dependent acute renal failure, with cast nephropathy, caused by monoclonal free light chains (FLC). Of these, 80 to 90% require long-term renal replacement therapy. Early treatment by plasma exchange reduces serum FLC concentrations, but randomized, controlled trials have shown no evidence of renal recovery. This outcome can be explained by the low efficiency of the procedure. A model of FLC production, distribution, and metabolism in patients with myeloma indicated that plasma exchange might remove only 25% of the total amount during a 3-wk period. For increasing FLC removal, extended hemodialysis with a protein-leaking dialyzer was used. In vitro studies indicated that the Gambro HCO 1100 dialyzer was the most efficient of seven tested. Model calculations suggested that it might remove 90% of FLC during 3 wk. This dialyzer then was evaluated in eight patients with myeloma and renal failure. Serum FLC reduced by 35 to 70% within 2 hr, but reduction rates slowed as extravascular re-equilibration occurred. FLC concentrations rebounded on successive days unless chemotherapy was effective. Five additional patients with acute renal failure that was caused by cast nephropathy then were treated aggressively, and three became dialysis independent. A total of 1.7 kg of FLC was removed from one patient during 6 wk. Extended hemodialysis with the Gambro HCO 1100 dialyzer allowed continuous, safe removal of FLC in large amounts. Proof of clinical value now will require larger studies.
Of newly diagnosed patients with multiple myeloma, 12–20% present with acute renal failure caused by monoclonal free light chains (FLCs). Plasma exchange can reduce the pre-renal load of FLCs but randomised controlled trials have shown no clinical benefit. This disappointing outcome can be explained by the low efficiency of the procedure. A model of FLC production, distribution and metabolism in myeloma patients indicated that plasma exchange might remove only 5–10% of the total body FLCs over a three-week period. To improve removal rates we have used prolonged hemodialysis with a protein leaking dialyser. In-vitro studies indicated that the Gambro HCO 1100 dialyser, with pores of 100kDa, was the most efficient of seven tested. This dialyser was used in 10 patients with myeloma and renal failure, as part of their hemodialysis treatment, to assess FLC removal efficiency. Three of the patients were studied at initial clinical presentation with biopsy proven FLC cast nephropathy. Routine chemotherapy was used, together with prolonged daily hemodialysis and multiple measurements of FLCs in serum, urine and dialysate fluid. Serum FLCs were reduced by 40 to 70% within one hour then reduction slowed as extravascular re-equilibration occurred. FLC concentrations rebounded on successive days until chemotherapy was effective. 1.5kg of FLCs was removed from one patient over 6 weeks and another became independent of dialysis. Prolonged hemodialysis allowed removal of 5–10 times more FLCs than plasma exchange without attendant clotting problems and removal of many serum proteins (Figure 1). Proof of clinical value will require further studies. Simulations of aFLC removal by plasma exchange versus hemodialysis on the Gambro HCO 1100. Simulations: 1) 100% tumor kill on day one with only reniculoendothetial removal; 2) 10% tumor kill per day reniculoendothetial removal alone; 3) 10% tumor kill per day with plasma exchange (3.5 liters exchange in 1.5 hrs × 6 over 10 days); 4) 10% tumor kill per day with hemodialysis for 4 hours, 3 times a week; 5) 10% tumor kill per day with hemodialysis for 4 hours per day; 6) 10% tumor kill per day with hemodialysis for 12 hours per day; 7) No tumor kill with 8 hours hemodialysis on alternate days 8) No tumor kill with no direct removal. Simulations of aFLC removal by plasma exchange versus hemodialysis on the Gambro HCO 1100. Simulations: 1) 100% tumor kill on day one with only reniculoendothetial removal; 2) 10% tumor kill per day reniculoendothetial removal alone; 3) 10% tumor kill per day with plasma exchange (3.5 liters exchange in 1.5 hrs × 6 over 10 days); 4) 10% tumor kill per day with hemodialysis for 4 hours, 3 times a week; 5) 10% tumor kill per day with hemodialysis for 4 hours per day; 6) 10% tumor kill per day with hemodialysis for 12 hours per day; 7) No tumor kill with 8 hours hemodialysis on alternate days 8) No tumor kill with no direct removal.
The Medi-Flex disinfection method offers the English National Blood Service a validated, optimal 'best practice' disinfection technique and should contribute significantly to the reduction in risk of transmission of bacteria by transfusion.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.