A degradable, poly (lactic-co-glycolic acid) (PLGA), gentamicin-loaded prophylactic coating for hydroxyapatite (HA)-coated cementless hip prostheses is developed with similar antibacterial efficacy as offered by gentamicinloaded cements for fixing traditional, cemented prostheses in bone. We describe the development pathway, from in vitro investigation of antibiotic release and antibacterial properties of this PLGA-gentamicin-HA-coating in different in vitro models to an evaluation of its efficacy in preventing implant-related infection in rabbits. Bone in-growth in the absence and presence of the coating was investigated in a canine model. The PLGAgentamicin-HA-coating showed high-burst release, with antibacterial efficacy in agar-assays completely disappearing after 4 days, minimising risk of inducing antibiotic resistance. Gentamicin-sensitive and gentamicinresistant staphylococci were killed by the antibiotic-loaded coating, in a simulated prosthesis-related interfacial gap. PLGA-gentamicin-HA-coatings prevented growth of bioluminescent staphylococci around a miniature-stem mounted in bacterially contaminated agar, as observed using bio-optical imaging. PLGA-gentamicin-HA-coated pins inserted in bacterially contaminated medullary canals in rabbits caused a statistically significant reduction in infection rates compared to HA-coated pins without gentamicin. Bone ingrowth to PLGA-gentamicin-HAcoated pins, in condylar defects of Beagle dogs was not impaired by the presence of the degradable, gentamicinloaded coating. In conclusion, the PLGA-gentamicin-HA-coating constitutes an effective strategy for infection prophylaxis in cementless prostheses.
Spectroscopic investigations of intermediates in the reaction of cytochrome P450(BM3)-F87G with surrogate oxygen atom donors. J. Inorg. Biochem. 100 (12), 2045-2053 (2006
When first introduced, total hip replacements offered pain relief and improved mobility in elderly patients. The success of this procedure in terms of long-term durability and restoration of function has led to its use in younger, more active patients. This has resulted in a commensurate increase in patient expectation regarding longevity and the degree to which function and lifestyle is restored. The bearing surface is a key feature of the performance of replacement joints. It is generally accepted that excessive amounts of wear debris preclude their long-term survivorship and hence there is an ongoing requirement for bearing surfaces which minimize debris generation. The purpose of this paper is to review the factors which affect the performance of so-called metal-on-metal bearings, to compare their performance with that of the other commonly used contemporary alternatives, metal and ceramic articulating against highly cross-linked polyethylene, and ceramic-on-ceramic, and finally to consider the potential solutions offered by new developments such as ceramic-on-metal and coatings applied to metal-on-metal bearings.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.