Poly(vinylidene fluoride/trifluoroethylene) copolymers of different molar ratios in the range between 60:40 and 80:20 have been studied by thermally stimulated processes, namely thermally stimulated depolarization current, thermally stimulated current and differential scanning calorimetry, and by dielectric constant measurements. The results obtained show unequivocally that a ferroelectric-to-ferroelectric phase transition exists for 70:30 and 75:25 copolymers, in addition to the well-known ferroelectric-to-paraelectric transition, which has already been observed in all copolymers.
This paper aims to analyze the thermal behavior and residual mechanical properties of concrete hollow-blocks structural masonry and its component materials in fire situation using experimental investigation. Compression tests were carried out on blocks, prisms and small walls at room temperature and after being exposed for 70 minutes to the ISO 834 Standard Fire. The test at high temperatures was run using a furnace powered by natural gas and instrumented with thermocouples to measure temperatures in the specimens. The influence of the initial concrete strength on masonry behavior was evaluated considering the use of blocks with different strengths at room temperature. In addition, exposure to fire was also investigated considering masonry elements with no coverings and submitted to two different fire exposure conditions: one or both sides. The results indicate a substantial loss in the masonry load capacity at high temperatures, especially in cases of fire exposure on both sides, where the residual compressive strength resulted, on average, between 20% and 27% for the blocks and approximately 14% for prisms and small walls. Its performance with fire heating up on only one face is much higher, with an average residual masonry strength equal to 46% compared to its strength at room temperature. The obtained results are also useful for evaluating masonry regarding the integrity and thermal insulation criteria, the latter achieved with little over 60 minutes of testing.
The bare steel structural members have a low fire resistance. However, in steel and concrete composite members, the concrete encasement, besides the contribution to the stiffness of the whole system, reduces the amount of heat that reaches the steel profile, increasing the its fire resistance. The aim of this paper is to conduct a numerical study on the behavior of steel and steel and concrete composite columns in fire, in order to compare their performance based on the variation of parameters such as the stiffness of the surrounding structure, geometric imperfection and load ratio. It has been found that, in general, the intensity of the geometric imperfection and stiffness of the surrounding structure does not affect the fire resistance of steel and composite columns. However, the stiffness of the surrounding structure raised the maximum value of the restraining forces generate throughout the heating. Regarding the load ratio, when increased, the fire resistance and critical temperature decreased.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.