We describe an outbreak of necrotizing enterocolitis (NEC) that occurred in the neonatal intensive care unit of our hospital. A total of 12 neonates developed NEC in June-July 1998. For two of them, twin brothers, the NEC turned out to be fatal. Enterobacter sakazakii, a known contaminant of powdered milk formula, was isolated from a stomach aspirate, anal swab, and/or blood sample for 6 of the 12 neonates. A review of feeding procedures revealed that 10 of the 12 patients were fed orally with the same brand of powdered milk formula. E. sakazakii was isolated from the implicated prepared formula milk as well as from several unopened cans of a single batch. Molecular typing by arbitrarily primed PCR (AP-PCR) confirmed, although partially, strain similarity between milk and patient isolates. No further cases of NEC were observed after the use of the contaminated milk formula was stopped. With this outbreak we show that intrinsic microbiological contamination of powdered milk formula can be a possible contributive factor in the development of NEC, a condition encountered almost exclusively in formula-fed premature infants. The use of sterilized liquid milk formula in neonatal care could prevent problems with intrinsic and extrinsic contamination of powdered milk formula.
Background
With the spread of coronavirus disease 2019 (COVID-19), an existing national laboratory-based surveillance system was adapted to daily monitor the epidemiological situation of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in the Belgium by following the number of confirmed SARS-CoV-2 infections, the number of performed tests and the positivity ratio. We present these main indicators of the surveillance over a one-year period as well as the impact of the performance of the laboratories, regarding speed of processing the samples and reporting results, for surveillance.
Methods
We describe the evolution of test capacity, testing strategy and the data collection methods during the first year of the epidemic in Belgium.
Results
Between the 1st of March 2020 and the 28th of February 2021, 9,487,470 tests and 773,078 COVID-19 laboratory confirmed cases were reported. Two epidemic waves occurred, with a peak in April and October 2020. The capacity and performance of the laboratories improved continuously during 2020 resulting in a high level performance. Since the end of November 2020 90 to 95% of the test results are reported at the latest the day after sampling was performed.
Conclusions
Thanks to the effort of all laboratories a performant exhaustive national laboratory-based surveillance system to monitor the epidemiological situation of SARS-CoV-2 was set up in Belgium in 2020. On top of expanding the number of laboratories performing diagnostics and significantly increasing the test capacity in Belgium, turnaround times between sampling and testing as well as reporting were optimized over the first year of this pandemic.
Congenital toxoplasmosis (CT) and cytomegalovirus infection (cCMV) may cause significant morbidity and even fetal or neonatal mortality. We aimed to quantify the disease burden of CT and cCMV in Belgium in terms of disability-adjusted life years (DALYs) and identify data gaps. The public health impact of CT and cCMV in Belgium in 2013 was 188 (95% uncertainty interval [UI], 43-419) and 1976 (95% UI, 757-4067) DALYs, respectively. The major data gaps identified were representative Belgian studies; information on important sequelae, intrauterine mortality, and termination of pregnancy; and late onset sequelae. A scenario analysis showed important increases in years of life lost when the burden due to fetal losses was included and decreases in DALYs when comprehensive CT prevention measures were conducted. Addressing the key data gaps identified may allow generation of the data needed to break the vicious circle of underrecognition.
Kaposi's sarcoma (KS) is a rare cutaneous tumor caused by human herpes virus-8 (HHV-8) infection that preferentially develops in case of severe immunosuppression, such as in HIV/AIDS disease. Haptoglobin (Hp), a polymorphic multifunctional plasma protein, exerts several immunomodulatory effects and is characterized by a genetic polymorphism leading to three major phenotypes (Hp 1-1, Hp 2-1 and Hp 2-2). This study investigated the influence of Hp genetic polymorphism on the development of KS in HIV-positive patients. 661 HIV patients were enrolled in the study with a median age of 35 years and a median follow-up time of 57 months. Hp phenotyping was performed using hemoglobin-supplemented starch gel electrophoresis. In case of low Hp concentration high pressure gel permeation chromatography (HPGPC) was used. The Hp 1-1 phenotype was associated with a significant higher risk of KS compared to the combined group of Hp 2-1 and Hp 2-2 patients (p < 0.0005) which remained significant after adjustment for possible confounding variables (age, gender and AIDS status) (p < 0.001). In contrast, the Hp 2-1 phenotype carried the lowest risk. These findings point to the involvement of Hp phenotypes in the pathogenesis of KS, which may be due to a difference in skin immunosurveillance between the Hp phenotypes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.