The purpose of this in vitro study was to evaluate the effect of different surface treatments on the shear bond strength of a resin-based cement to porcelain. Sixty pairs of 50% aluminous porcelain discs were fabricated. In each pair, one disc measured 6 mm in diameter X 3 mm thickness (A) and the other measured 3 mm in diameter X 3mm thickness (B). The specimens were randomly assigned to 6 groups (n=10 pairs of discs), according to the surface treatment: etching with 10% hydrofluoric acid for 2 or 4min (G1 and G2); 50-μm particle aluminum oxide sandblasting for 5 s (G3); sandblasting followed by etching for 2 or 4min (G4 and G5) and control -no treatment (G6). A silane agent was applied to the treated surface of both discs of each pair. Bistite II DC dual-cure resin cement was applied and the B discs were bonded to their respective A discs. Specimens were stored in distilled water at 37ºC for 24 h and were tested in shear strength at a crosshead speed of 2 mm/min. Means in MPa were: G1: 14.21 ± 4.68; G2: 8.92 ± 3.02; G3: 10.04 ± 2.37; G4: 12.74 ± 5.15; G5: 10.99 ± 3.35; G6: 6.09 ± 1.84. Data were compared by one-way ANOVA and Tukey's test at 5% significance level. Bond strength recorded after 2-min acid etching was significantly higher than 4-min etching (p<0.05) and control (p<0.05), but did not differ significantlyfrom sandblasting alone (p>0.05) or followed by etching for 2 or 4 min (p>0.05). Within the limitations of an in vitro study, it may be concluded that 2-min hydrofluoric acid etching produced a favorable micromechanical retention that enhanced resin cement bond strength to porcelain.
RESUMOObjetivo: Avaliar, in vitro a micromorfologia da interface da união sistema restaurador-dentina decídua, em função do sistema adesivo e do instrumento cortante rotatório. Método: Foram utilizados 20 segundos molares decíduos divididos aleatoriamente em dois grupos (n=10). No grupo C, foi realizado desgaste, até atingir a dentina, com ponta carbide. No grupo D, foi feito o mesmo desgaste, porém com ponta diamantada. A superfície preparada de cada dente foi dividida ao meio, sendo que em uma metade foi aplicado um sistema adesivo convencional de duas etapas (Single-Bond -3M) e na outra um sistema autocondicionante de etapa única (One Up Bond F -Tokuyama). Todos os dentes foram restaurados com a resina composta híbrida (Filtek Z250 -3M). As amostras foram termocicladas, embutidas em resina, seccionadas para obtenção da interface de união e preparadas para observação ao MEV. Resultados: Os dois sistemas adesivos utilizados foram capazes de formar camada híbrida. O sistema adesivo convencional de duas etapas proporcionou melhor selamento da interface de união, quando comparada ao autocondicionante e o emprego da ponta diamantada com o adesivo autocondicionante, mostrou o pior selamento da interface de união, com os maiores valores de gap. Conclusão: O instrumento cortante rotatório (ponta diamantada) só apresentou influência negativa na qualidade da interface sistema restaurador-dentina decídua quando se empregou sistema adesivo autocondicionante de etapa única. DESCRIPTORS DESCRITORESInstrumentos odontológicos; Adesivos dentinários; Dente decíduo. Purpose:To evaluate, in vitro, the micromorphology of the restorative system-primary dentin interface as a function of the adhesive system and rotary cutting instrument. Method: Twenty primary second molars were randomly assigned to two groups (n=10). In group C, the teeth were ground with a carbide bur until reaching the dentin. In group D, the same procedure was done however using a diamond bur. The prepared surface of each tooth was bisected. In one half, a 2-step total-etch adhesive system (Single-Bond -3M) was applied and in the other half, a 1-step self-etching adhesive system (One Up Bond F -Tokuyama) was applied. All teeth were restored with a hybrid composite resin (Filtek Z250 -3M). The specimens were thermocycled, embedded in resin, sectioned to obtain the adhesive interface and prepared for SEM analysis. Results: Both adhesive systems were capable of forming a hybrid layer. The 2-step total-etch adhesive system provided a better sealing of the adhesive interface, in comparison to the self-etching adhesive system. The use of a diamond bur together with the selfetching adhesive system yielded the worst sealing of the adhesive interface, with presence of larger gaps. Conclusions: The rotary cutting instrument (diamond bur) had a negative influence on the quality of the restorative system-primary dentin interface only when a 1-step self-etching adhesive system was used.Dental instruments; Adhesive system; Deciduous tooth.
O objetivo deste estudo foi investigar in vitro o comportamento das facetas de Artglass e Targis quando submetidas à inserção e remoção de grampos circunferenciais de cromocobalto. Foram confeccionadas 24 coroas veneer (12 com facetas de Artglass e 12 com Targis), bem como os respectivos grampos circunferenciais em cromo-cobalto. Utilizando um dispositivo elaborado para este fim, as coroas foram submetidas a cinco mil ciclos de inserção e remoção dos grampos. Para avaliar os efeitos dos ciclos sobre os corpos-de-prova, foram utilizadas a verificação da força necessária para remover os grampos das coroas e a inspeção macroscópica das coroas. A força necessária para remoção dos grampos das coroas não foi alterada significativamente durante o experimento. Entretanto, todas as coroas apresentaram uma área de abrasão, observável por inspeção visual. Deste modo, é possível depreender que as facetas feitas com Artglass e Targis sofrem abrasão decorrente da inserção e remoção de grampos circunferenciais em cromo-cobalto, mas esta abrasão não influenciou significativamente a força necessária para remover o grampo da coroa durante este estudo.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.