PURPOSE: To develop and validate a psychometric scale for assessing Image quality perception for chest radiographs.METHODS: A review of the literature was undertaken to identify items/factors which could be used to evaluate image quality using a perceptual approach. A draft scale was then created (22 items) and presented to a focus group (student, qualified radiographers and radiology registers). Within the focus group the draft scale was discussed and modified. A series of seven postero-anterior chest images were generated using a phantom with a range of image qualities. Image quality perception was initially confirmed for the seven images using signal-to-noise ratio (SNR) and group consensus. Participants were invited to independently score each of the images using the draft image quality perception scale. Bandura's theory was used to guide scale development and Cronbach alpha was used to test interval reliability.RESULTS: Fifty three participants used the scale to grade image quality perception on each of the seven images (SNR 17.2 to 36.5). Aggregated mean scale score increased with increasing SNR from 42.1 to 87.7 (r=0.98, P<0.001). For each of the 22 individual scale items there was clear differentiation of low, mid and high-quality images. A Cronbach alpha coefficient of >0.7 was obtained across each of the seven images.CONCLUSION: This study represents the first development of a chest image quality perception scale based on Bandura's theory. There was excellent correlation between the image quality perception scores derived using the scale and the SNR and group consensus. Further research will involve a more detailed item and factor analysis.
ObjectivesThis pilot study aimed to characterize and compare radiographers’ mammography practice, including quality control and continuous professional development in five European countries.MethodsOnline survey was performed to collect data regarding participants’ profile, institution’s profile, mammography practice, quality control and continuous professional development. The questionnaire was sent to clinical radiographers working in Estonia, Finland, Norway, Portugal and Switzerland. Descriptive statistical and subgroup analyzes were performed.ResultsThe amount of returned questionnaires was 140. Most respondents were female (92%), having radiography bachelor. The majority (89%) of radiographers was working with full-field digital mammography. The majority (97%) of mammography images were acquired using AEC, and half of the radiographers were using dose saving programmes suggested by the manufacturers. The most typical (50%) compression force ranged from 8 to 11 kg. Part of the radiographers (44%) did not know if their practice followed specific guidelines. The most challenging tasks in mammography identified by radiographers were patient positioning (86%), coping with pain (88%), managing anxiety (83%) and imaging breast implants (71%). The majority (88%) of the respondents undertook continuous professional development activities.ConclusionsThe mammography practice varies across the five countries. We found country-specific traits related to mammography image acquisition, patient-centered care and quality management procedures. The lack of evidence-based knowledge suggests the importance of well-designed studies on these topics. The variability found in this pilot study encourages radiographers to question their own practice and teachers to review and revise the training programmes. Validation in larger studies including more countries is needed.
Introduction: With the introduction of digital radiography, the feedback between image quality and overexposure has been partly lost which in some cases has led to a steady increase in dose. Over the years the introduction of exposure index (EI) has been used to resolve this phenomenon referred to as 'dose creep'. Even though EI is often vendor specific it is always a related of the radiation exposure to the detector. Due to the nature of this relationship EI can also be used as a patient dose indicator, however this is not widely investigated in literature. Methods: A total of 420 dose-area-product (DAP) and EI measurements were taken whilst varying kVp, mAs and body habitus on two different anthropomorphic phantoms (pelvis and chest). Using linear regression, the correlation between EI and DAP were examined. Additionally, two separate region of interest (ROI) placements/per phantom where examined in order to research any effect on EI. Results: When dividing the data into subsets, a strong correlation between EI and DAP was shown with all R-squared values > 0.987. Comparison between the ROI placements showed a significant difference between EIs for both placements. Conclusion:This research shows a clear relationship between EI and radiation dose which is dependent on a wide variety of factors such as ROI placement, body habitus. In addition, pathology and manufacturer specific EI's are likely to be of influence as well. Implications for practice: The combination of DAP and EI might be used as a patient dose indicator. However, the influencing factors as mentioned in the conclusion should be considered and examined before implementation.
BackgroundOur aim was to characterize the influence of time-of-flight (TOF) and point spread function (PSF) recovery corrections, as well as ordered subset expectation maximization (OSEM) reconstruction parameters, in 82Rb PET/CT quantification of myocardial blood flow (MBF) and myocardial flow reserve (MFR).Rest and stress list-mode dynamic 82Rb PET acquisition data from 10 patients without myocardial flow defects and 10 patients with myocardial blood flow defects were reconstructed retrospectively. OSEM reconstructions were performed with Gaussian filters of 4, 6, and 8 mm, different iterations, and subset numbers (2 × 24; 2 × 16; 3 × 16; 4 × 16). Rest and stress global, regional, and segmental MBF and MFR were computed from time activity curves with FlowQuant© software. Left ventricular segmentation using the 17-segment American Heart Association model was obtained.ResultsWhole left ventricle (LV) MBF at rest and stress were 0.97 ± 0.30 and 2.30 ± 1.00 mL/min/g, respectively, and MFR was 2.40 ± 1.13. Concordance was excellent and all reconstruction parameters had no significant impact on MBF, except for the exclusion of TOF which led to significantly decreased concordance in rest and stress MBF in patients with or without perfusion defects on a coronary artery basis and in MFR in patients with perfusion defects.ConclusionsChanges in reconstruction parameters in perfusion 82Rb PET/CT studies influence quantitative MBF analysis. The inclusion of TOF information in the tomographic reconstructions had significant impact in MBF quantification.
No abstract
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.