BACKGROUND CONTEXT: The contribution of anatomical structures to the stability of the spine is of great relevance for diagnostic, prognostic and therapeutic evaluation of spinal pathologies. Although a plethora of literature is available, the contribution of anatomical structures is still not well understood. PURPOSE: We aimed to quantify the biomechanical relevance of each of the passive spinal structure trough deliberate biomechanical test series using a stepwise reduction approach on cadavers. STUDY DESIGN: Biomechanical cadaveric study. METHODS: Fifty lumbar spinal segments originating from 22 human lumbar cadavers were biomechanically tested in a displacement-controlled stepwise reduction study: the intertransverse ligaments, the supraspinous and interspinous ligaments, the facet joint capsules (FJC), the facet joints (FJ), the ligamentum flavum (LF), the posterior longitudinal ligament (PLL), and the anterior longitudinal ligament were subsequently reduced. In the intact state and after each transection step, the segments were physiologically loaded in flexion, extension, axial rotation (AR), lateral bending (LB) and with anterior (AS), posterior (PS) and lateral shear (LS). Thirty-two specimens with only minor degeneration, representing a reasonably healthy subpopulation, were selected for the here presented evaluation. Quantitative values for load and spinal level dependent contribution patterns for the anatomical structures were derived. RESULTS: Small variability between of the contribution patterns are observed. The intervertebral disc (IVD) is exposed to about 67% of the applied load in LB and during shear loading, but less by load in flexion, extension and AR (less than 35%). The FJ&FJC are the main stabilizers in AR with 49%, but provide only 10% of the stability in extension. Beside the IVD, the LF and the PLL contribute mainly in flexion (22% and 16%, respectively), while the ALL plays a major role during extension (40%) and also contributes during LB (15%). The contribution of the intertransverse ligaments and the supraspinous and interspinous ligaments are very small in all loading directions (<2% and <6%, respectively). CONCLUSION: The IVD takes the main load in LB and absorbs shear loading, while the FJ&FJC stabilize AR. The ALL resists extension while LF and PLL stabilize flexion. With the small variability of contribution patterns, suggesting distinct adaptation of the structures to one another, the biomechanical characteristics of one structure have to be put in context of the whole spinal segment.
BACKGROUND CONTEXT Due to recent developments in augmented reality with headmounted devices, holograms of a surgical plan can be displayed directly in the surgeon's field of view. To the best of our knowledge, three dimensional (3D) intraoperative fluoroscopy has not been explored for the use with holographic navigation by head-mounted devices in spine surgery. PURPOSE To evaluate the surgical accuracy of holographic pedicle screw navigation by head-mounted device using 3D intraoperative fluoroscopy. STUDY DESIGN In this experimental cadaver study, the accuracy of surgical navigation using a head-mounted device was compared with navigation with a state-of-the-art posetracking system. METHODS Three lumbar cadaver spines were embedded in nontransparent agar gel, leaving only commonly visible anatomy in sight. Intraoperative registration of preoperative planning was achieved by 3D fluoroscopy and fiducial markers attached to lumbar vertebrae. Trackable custom-made drill sleeve guides enabled real-time navigation. In total, 20 K-wires were navigated into lumbar pedicles using AR-navigation, 10 K-wires by the state-of-the-art pose-tracking system. 3D models obtained from postexperimental CT scans were used to measure surgical accuracy. MF is the founder and shareholder of Incremed AG, a Balgrist University Hospital start-up focusing on the development of innovative techniques for surgical executions. The other authors declare no conflict of interest concerning the contents of this study. No external funding was received for this study. RESULTS No significant difference in accuracy was measured between AR-navigated drillings and the gold standard with pose-tracking system with mean translational errors between entry points (3D vector distance; p=.85) of 3.4±1.6 mm compared with 3.2±2.0 mm, and mean angular errors between trajectories (3D angle; p=.30) of 4.3°±2.3°compared with 3.5°±1.4°. CONCLUSIONS In conclusion, holographic navigation by use of a head-mounted device achieve accuracy comparable to the gold standard of high-end pose-tracking systems. CLINICAL SIGNIFICANCE These promising results could result in a new way of surgical navigation with minimal infrastructural requirements but now have to be confirmed in clinical studies.
Background: Precise insertion of pedicle screws is important to avoid injury to closely adjacent neurovascular structures. The standard method for the insertion of pedicle screws is based on anatomical landmarks (free-hand technique). Head-mounted augmented reality (AR) devices can be used to guide instrumentation and implant placement in spinal surgery. This study evaluates the feasibility and precision of AR technology to improve precision of pedicle screw insertion compared to the current standard technique. Methods: Two board-certified orthopedic surgeons specialized in spine surgery and two novice surgeons were each instructed to drill pilot holes for 40 pedicle screws in eighty lumbar vertebra sawbones models in an agarbased gel. One hundred and sixty pedicles were randomized into two groups: the standard free-hand technique (FH) and augmented reality technique (AR). A 3D model of the vertebral body was superimposed over the AR headset. Half of the pedicles were drilled using the FH method, and the other half using the AR method. Results: The average minimal distance of the drill axis to the pedicle wall (MAPW) was similar in both groups for expert surgeons (FH 4.8 ± 1.0 mm vs. AR 5.0 ± 1.4 mm, p = 0.389) but for novice surgeons (FH 3.4 mm ± 1.8 mm, AR 4.2 ± 1.8 mm, p = 0.044). Expert surgeons showed 0 primary drill pedicle perforations (PDPP) in both the FH and AR groups. Novices showed 3 (7.5%) PDPP in the FH group and one perforation (2.5%) in the AR group, respectively (p > 0.005). Experts showed no statistically significant difference in average secondary screw pedicle perforations (SSPP) between the AR and the FH set 6-, 7-, and 8-mm screws (p > 0.05). Novices showed significant differences of SSPP between most groups: 6-mm screws, 18 (45%) vs. 7 (17.5%), p = 0.006; 7-mm screws, 20 (50%) vs. 10 (25%), p = 0.013; and 8-mm screws, 22 (55%) vs. 15 (37.5%), p = 0.053, in the FH and AR group, respectively. In novices, the average optimal medio-lateral convergent angle (oMLCA) was 3.23°(STD 4.90) and 0.62°(STD 4.56) for the FH and AR set screws (p = 0.017), respectively. Novices drilled with a higher precision with respect to the cranio-caudal inclination angle (CCIA) category (p = 0.04) with AR. Conclusion: In this study, the additional anatomical information provided by the AR headset superimposed to realworld anatomy improved the precision of drilling pilot holes for pedicle screws in a laboratory setting and decreases the effect of surgeon's experience. Further technical development and validations studies are currently being performed to investigate potential clinical benefits of the herein described AR-based navigation approach.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.