Objective This study was performed to evaluate physician radiation doses with the use of a suspended lead suit. Background Interventional cardiologists face substantial occupational risks from chronic radiation exposure and wearing heavy lead aprons. Methods Head‐level physician radiation doses, collected using real‐time dosimeters during consecutive coronary angiography procedures, were compared with the use of a suspended lead suit versus conventional lead aprons. Multiple linear regression analyses were completed using physician radiation doses as the response and testing patient variables (body mass index, age, sex), procedural variables (right heart catheterization, fractional flow reserve, percutaneous coronary intervention, radial access), and shielding variables (radiation‐absorbing pad, accessory lead shield, suspended lead suit) as the predictors. Results Among 1054 coronary angiography procedures, 691 (65.6%) were performed with a suspended lead suit and 363 (34.4%) with lead aprons. There was no significant difference in dose area product between groups (61.7 [41.0, 94.9] mGy·cm2 vs. 64.6 [42.9, 96.9] mGy·cm2, p = 0.20). Median head‐level physician radiation doses were 10.2 [3.2, 35.5] μSv with lead aprons and 0.2 [0.1, 0.9] μSv with a suspended lead suit (p < 0.001), representing a 98.0% reduced dose with suspended lead. In the fully adjusted regression model, the use of a suspended lead suit was independently associated with a 93.8% reduction (95% confidence interval: −95.0, −92.3; p < 0.001) in physician radiation dose. Conclusion Compared to conventional lead aprons, the use of a suspended lead suit during coronary angiography was associated with marked reductions in head‐level physician radiation doses.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.