Background: Sonography is a valuable tool in the assessment of porto-systemic pathologies. This study aimed at determining the mean portal vein diameter based on age, gender and anthropometric variables. Methods: A cross sectional study conducted among 201 apparently healthy adults in Bauchi Metropolis. Participants were recruited from the school of nursing AbubakarTafawa Balewa Teaching Hospital (ATBUTH), Bauchi. Ultrasound machine ALOKA SSD-1000, (IP-1233EV, SN-57324, Japan) with curvilinear transducer with frequency of 3-5MHz was used for a period of four months, (December 2015 to April 2016). Participants' heights were measured while standing against a meter rule with the head in Frankfurts' position and weight measured using a weighing scale. Data analysis was done using SPSS version 22.0. Descriptive statistics (mean, standard deviation), and Pearson's Correlation were used. Results: The mean portal vein diameter was 9.60 ± 1.41mm for both sexes. The mean value for males was 9.71 ± 1.42mm, and 9.35±1.46mm among females. There was a positive correlation correlation between the PV diameter and Body Mass Index (P ≤ 0.01). Conclusion: This study found the mean values of PV diameter in apparently healthy adults in our environment to be 9.60 ± 1.41mm and that PV diameter positively correlates with anthropometric variables.
BackgroundReal-time ultrasound scanning is increasing in popularity as a teaching tool for human anatomy because it is non-invasive, offers real-time 3-D anatomy and is cheaper than dissections.ObjectivesTo assess real-time ultrasound scanning as a teaching method of human anatomy, and to determine what teaching methods radiography students consider effective for understanding human anatomy.Materials and methodsOne hundred and ten self-administered, structured and pre-tested questionnaires were distributed to Clinical Radiography students (Third, fourth and fifth year)in Northern Nigeria featuring University of Maiduguri and Bayero University Kano. The questionnaire consists of two sections;Demographics and preferred methods of delivery of anatomical information. Participation was voluntary. Comparisons among teaching methods were made using repeated measures ANOVA.ResultsA significant difference among the eight delivery methods with 3-D Radiology imaging being as the most preferred method overall (48.17, p<0.0001) and ultrasound the least (32.48, p<0.0001). With Duncan's multiple Range test, it is clearly shown that 3-D Radiology imaging differ with mean value(5.2522) followed by Computer programs(5.1292), Anatomic models( 4.7593), Laboratory videos(4.5815), textbooks(4.5358), animal dissection(4.2568), lectures(3.2568) and finally ultrasound scan (3.6087), (P<0.0001).Conclusion3-D Radiology imaging is the most preferred method of delivering anatomical information and ultrasound scanning is the least preferred method.
Objective: To determine the normal value of amniotic fluid (AF) volume among pregnant women in a Northern Nigerian population and to determine if there is a relationship between AF index (AFI) and single deepest pocket (SDP) with anthropometric variables. Materials and Methods: A prospective cross-sectional study was conducted among singleton pregnant women at late second and third trimester attending the antenatal clinic in Abubakar Tafawa Balewa Teaching Hospital, Bauchi, from December 2016 to April 2017. The mean AFI and SDP were measured by sonography. Ethical approval was obtained from the institution and informed consent was sought for from all the participants. Descriptive statistics, i.e. mean, standard deviation, and correlation coefficient, were used for the analysis. Results: A total of 206 women, aged between 18 and 40 years, with fetal gestational ages between 22 and 39 weeks were included in the study. The values for AFI in the study ranged from 12 to 28.7 cm, with a mean value of 19.84 ± 3.64 cm, and SDP ranged from 3.7 to 9.1 cm with a mean value of 6.04 ± 1.12 cm. This study found a weak relationship between the anthropometric variables and AFI and SDP and a strong relationship between AFI and SDP with a correlation coefficient of R = 0.901 and P = 0.014. Conclusion: This study found the mean values for AF volume using AFI and SDP in the studied population to be 19.84 ± 3.64 cm and 6.04 ± 1.12 cm, respectively; a strong positive relationship between AFI and SDP; and a negative relationship between body mass index with AFI and SDP.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.