BackgroundReference values are very important in clinical management of patients, screening participants for enrolment into clinical trials and for monitoring the onset of adverse events during these trials. The aim of this was to establish gender-specific haematological and biochemical reference values for healthy adults in the central part of Ghana.MethodsA total of 691 adults between 18 and 59 years resident in the Kintampo North Municipality and South District in the central part of Ghana were randomly selected using the Kintampo Health and Demographic Surveillance System and enrolled in this cross-sectional survey. Out of these, 625 adults made up of 316 males and 309 females were assessed by a clinician to be healthy. Median values and nonparametric 95% reference values for 16 haematology and 22 biochemistry parameters were determined for this population based on the Clinical Laboratory and Standards Institute guidelines. Values established in this study were compared with the Caucasian values being used currently by our laboratory as reference values and also with data from other African and western countries.ResultsReference values established include: haemoglobin 113–164 g/L for males and 88–144 g/L for females; total white blood cell count 3.4–9.2×109/L; platelet count 88–352×109/L for males and 89–403×109/L for females; alanine aminotransferase 8–54 U/L for males and 6–51 U/L for females; creatinine 56–119 µmol/L for males and 53–106 µmol/L for females. Using the haematological reference values based on the package inserts would have screened out up to 53% of potential trial participants and up to 25% of the population using the biochemical parameters.ConclusionWe have established a panel of locally relevant reference parameters for commonly used haematological and biochemical tests. This is important as it will help in the interpretation of laboratory results both for clinical management of patients and safety monitoring during a trial.
SUMMARYObjectives: To estimate the reference intervals for commonly used blood haematology and biochemical parameters in an adult (18-55yrs) population of residents of Mampong Akuapem. Design: This was a population based cross sectional study of a randomly selected sample of the adult population of Mampong. The sample was selected from an updated census list of the Mampong area. Conclusion:In comparison to reference values that are commonly used in Ghana, the haemoglobulin levels from this study were lower, and liver function parameters higher. This could be a result of genetic or environmental differences and calls for the need to establish site specific reference values applicable to our population
BackgroundTo prepare field sites for malaria vaccine trials, it is important to determine baseline antibody and T cell responses to candidate malaria vaccine antigens. Assessing T cell responses is especially challenging, given genetic restriction, low responses observed in endemic areas, their variability over time, potential suppression by parasitaemia and the intrinsic variability of the assays.MethodsIn Part A of this study, antibody titres were measured in adults from urban and rural communities in Ghana to recombinant Plasmodium falciparum CSP, SSP2/TRAP, LSA1, EXP1, MSP1, MSP3 and EBA175 by ELISA, and to sporozoites and infected erythrocytes by IFA. Positive ELISA responses were determined using two methods. T cell responses to defined CD8 or CD4 T cell epitopes from CSP, SSP2/TRAP, LSA1 and EXP1 were measured by ex vivo IFN-γ ELISpot assays using HLA-matched Class I- and DR-restricted synthetic peptides. In Part B, the reproducibility of the ELISpot assay to CSP and AMA1 was measured by repeating assays of individual samples using peptide pools and low, medium or high stringency criteria for defining positive responses, and by comparing samples collected two weeks apart.ResultsIn Part A, positive antibody responses varied widely from 17%-100%, according to the antigen and statistical method, with blood stage antigens showing more frequent and higher magnitude responses. ELISA titres were higher in rural subjects, while IFA titres and the frequencies and magnitudes of ex vivo ELISpot activities were similar in both communities. DR-restricted peptides showed stronger responses than Class I-restricted peptides. In Part B, the most stringent statistical criteria gave the fewest, and the least stringent the most positive responses, with reproducibility slightly higher using the least stringent method when assays were repeated. Results varied significantly between the two-week time-points for many participants.ConclusionsAll participants were positive for at least one malaria protein by ELISA, with results dependent on the criteria for positivity. Likewise, ELISpot responses varied among participants, but were relatively reproducible by the three methods tested, especially the least stringent, when assays were repeated. However, results often differed between samples taken two weeks apart, indicating significant biological variability over short intervals.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.