Purpose CAD/CAM technology is a newer technique for creating spinal orthoses than standard plaster molded methods. To our knowledge there has been only one previous study of CAD/CAM braces. The purpose of our study was to compare patient preference and in-brace correction of Cobb angle between plaster molded thoracolumbosacral orthoses (TLSO) and CAD/CAM designed TLSOs in a series of patients with scoliosis. Methods Ten patients with an average initial Cobb angle of 30.8°(range 18°-46°) had both a plaster molded TLSO and a CAD/CAM TLSO fabricated for them. In each case, the decision to brace was made by the treating surgeon based on curve magnitude and skeletal maturity. After 3 weeks of 23 h a day wear, in-brace correction of the Cobb angle was measured for each brace based on standard PA spine radiographs. After 3 months of use, patients were asked which brace they preferred. Results For the CAD/CAM brace, the mean curve correction after 3 months was 51% compared to 44% in the plaster molded TLSO cohort. (p = 0.46). Seven out of nine patients preferred the CAD/CAM TLSO over the plaster molded TLSO. There were no brace complications in either group. Conclusion In our matched cohort study, CAD/CAM TLSOs had at least equivalent if not superior correction of the Cobb angle compared to standard plaster molded TLSOs; 78% of our patients preferred the CAD/CAM brace over the standard TLSO.
A total of 79% of patients with TIS were less than 5 percentile in weight, thus meeting the criteria for "failure to thrive." Our study demonstrates a significant improvement in the nutritional status of these children after VEPTR surgery, which is an important outcome measure in this population.
Background Studies have shown that when using a spica cast following hip surgery in children , there are associated complications such as soiling, pressure sores, and osteopenic fractures. Methods Charts were retrospectively reviewed for all patients who had undergone hip surgeries by one surgeon at one institution between 1999 and 2005. The method of post-operative immobilization (spica cast or abduction pillow) and complications were recorded for each patient.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.